SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE •
SERVICE
MAIN CONTROL
The main control board is very robust and is rarely the
cause of system issues. It is important to fully diagnose
the board for any suspected failures before attempting to
remove the board for replacement or service. Follow the
guidelines below to fully test and diagnose the main
control.
Power Fault
If the unit does not (or seems to not) power on, follow the
flow chart below to help diagnose the issue. Before
beginning it is important to first verify the unit is not
simply set to sabbath mode.
ALL ERRORS
The All Errors option keeps record of any system errors.
When an error occurs it is recorded to all errors. The
number next to the error indicates the number of recorded
instances. Errors in the log may not be currently active.
The error log memory is non volatile and is persistent
should power be lost and restored to the unit. See below
for a list of logged errors and their respective descriptions.
To access All Errors follow the steps below.
1. Press
to select “All Errors”.
Check Voltage
At Wall Outlet
Verify Voltage
At Main Control
Voltage Input
Check Fuse F1
For Continuity
Open Door.
Is the UI Now
Functional?
Replace Main
Board
Replace Reed
Switch.
Replace
Fuse
Replace
Power Cord
Alert Customer
Of Power Failure
Is the Reed
Switch Operating
Properly?
Is the door open? The
Display will not activate
while the door is closed
Inspect Customer UI
and Data Cable
Connect Test Display
To J5.
Cycle Power And
Check For Operation
No Voltage
No Voltage
Voltage
Continuity
Operating
Not Operating
No Continuity
No
No
No
Yes
Yes
Yes
Voltage
ID
Description
Solution
No Comm
Unit lost
communication
to the display.
Check display cable.
Replace if necessary.
Bin T Open Bin thermistor circuit
open.
Check connection.
Replace if necessary.
Condenser
T Open
Condenser
thermistor circuit
open.
Check connection.
Replace if necessary.
Bin T Short Bin thermistor circuit
shorted.
Check connection.
Replace if necessary.
Condenser
T Short
Condenser
thermistor circuit
shorted.
Check connection.
Replace if necessary.
Temp Hi
6H+
Not used.
Not used.
Temp Hi
12H+
Not used.
Not used.
Temp Lo
6H+
Not used.
Not used.
Temp Lo
12H+
Not used.
Not used.
Door Open
5M
Door switch open for
more then 5
minutes.
Check reed switch and
connection.
Time To
Clean
Water circulation
system requires
cleaning.
Clean unit with 37050
cleaner.
Blocked
Drain
Drain pump has
detected a problem.
Check drain hose for
restriction or drain pump
for correct operation.
Up
Error ID
Number
Of Occurrences
Select
Down
RETURN TO MENU
ALL ERRORS
NO COMM 0
ZONE T OPEN 0
51