USER GUIDE
Cutout Dimensions 1
SAFETY •
INSTALLATION & INTEGRATION
• OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Cutout Dimensions
PREPARE SITE
Your U-Line product has been designed exclusively for a
built-in installation. When built-in, your unit does not
require additional air space for top, sides, or rear.
However, the front grille (plinth strip/base fascia) must
NOT be obstructed.
The product is designed and manufactured for seamless
integration in the specified cutout opening shown, which
requires precise measurements. The opening must be
square and plumb front to back. Although not required,
you may choose to increase the overall cutout width for
ease of installation.
The Modular 3000 Series units are engineered with a
variety of adjustment features to help ensure a seamless
installation. Adjustable doors, leveling legs and grille will
assist in fine tuning the installation.
All 3000 Series models fully integrate into overlay/face
frame, inset or European/frameless cabinet styles.
CAUTION
!
Unit can NOT be installed behind a closed cabinet
door.
For cabinet depths less than 24-3/8" (620 mm),
electrical socket MUST be located in the adjacent
cabinet or recessed in the wall. The power cord
length is 6ft (180 cm).
CUTOUT DIMENSIONS
Metric measurements rounded and optimized
.
17-7/8"
(455 mm)
33-7/8"
(860 mm)
to
34-7/8"
(886 mm)
Preferred location
for drain, water
line and receptacle
is in adjacent
cabinet.
24"
(610 mm)
5/8"
(16 mm)
9