General Information

To Initiate quick chill

1. Use Zone Select 

 to select the desired zone, left or right.

2. Press Select 

 to select the desired mode setting.

3. Press Down 

 until the temperature set point reads “Quick”.

The quick chill feature will then begin for the period of time dictated 
by the mode type. To cancel quick chill simply select a set point other 
then “quick”.

Note: 

There may be a delay before quick chill is activated. If the 

opposite zone is currently in a cooling cycle and quick chill is 

selected, the cooling cycle on the opposite side will first be 

completed before beginning quick chill.

Note: 

When quick chill is activated, the zone opposite the active quick 

chill zone will not return to a cooling cycle until quick chill is 

complete. If storing product in the opposite zone, it is important to 

limit the number of times the door is opened in the zone not 

currently under quick chill. 

Interior Lighting

U-Line 3000 Series unit uses a state of the art theatre style LED 
lighting system. 

Note: 

Lighting system is designed to fade in and out when switching 

states.

1. To begin, press U-Select Lighting 

 to enter the lighting menu. 

2. The unit initially defaults to control the lighting in both Zones 

simultaneously. To select a single zone press Zone Toggle 

Notice the arrows on top of the display changing state. Pressing 
Zone Toggle 

 once will select the left side zone, pressing it 

again will select the right side zone, pressing it a third time will 
select both zones again.

3. Use Up 

 or Down 

 to cycle through each available 

brightness setting; Low, Medium, or High.

4. Use U-Select Lighting 

 to cycle through each available timer 

setting. Selections include “On With Door”, “On 3 Hours”, “On 
6 Hours”, or “On 24 Hours”.

5. To exit, press Select 

 or simply wait for the menu to time out.

Error Notification

The 3000 model series continuously monitors a series of inputs and 
parameters to ensure proper and efficient operation of the unit. Should 
the system detect a fault, an error notification will be displayed on the 
user interface. See below for a list of errors.

Customer Menu

The 3000 Series of U-Line undercounter refrigeration appliances 
contain a feature rich customer menu. The Customer Menu allows 
access to a series of advanced features including Energy Saver Mode, 
Sabbath mode, Actual Temperature readings as well as a method to 
restore factory defaults. 

1. To access the Customer Menu hold down Select 

 for 5 

seconds.

2. Use Up 

 or Down 

 to scroll through available selections.

3. Use Select 

 to enter selected sub-menu.

4. To exit Customer menu, Use Down 

 to scroll to the bottom 

of the display and use Select 

 to Select “Exit.”

Up

Zone Indicator

Zone Indicator

Zone Toggle

Select

Down

U-Select Lighting

Power

3036 Model Display Shown

U-SELECT LIGHTING

ON WITH DOOR

LIGHTING

HIGH

LEVEL

ID

Description

Solution

No Comm

Unit lost 

communication to the 

display.

Inspect Customer UI and 

Data Cable (if defective 

replace entire door)

(L) (R) Zone T 

Open

Left or right zone 

thermistor circuit 

open.

Check connection. 

Replace if necessary.

Amb Thrm Open

Ambient thermistor 

circuit open.

Check connection. 

Replace if necessary.

(L) (R) Zone T 

Short

Left or right zone 

thermistor circuit 

shorted.

Check connection. 

Replace if necessary.

Amb Thrm Short

Ambient thermistor 

circuit shorted.

Check connection. 

Replace if necessary.

(L) (R) Temp Hi 

6H+

Left or right Zone 

tempe5° over 

set point for over 6 

hours.

Verify door is closed and 

sealing. Contact customer 

care if persistent.

(L) (R) Temp Hi 

12H+

Zone tempe5° 

over set point for over 

12 hours.

Check compressor, 

evaporator fan and related 

relays and DC outputs.

(L) (R) Temp Lo 

6H+

Zone temperature

-5° under set point for 

over 6 hours.

Check compressor, 

evaporator fan and related 

relays and DC outputs.

(L) (R) Temp Lo 

12H+

Zone temperature

-5° under set point for 

over 12 hours.

Check compressor, 

evaporator fan and related 

relays and DC outputs.

(L) (R) Door 

Open 5M

Door switch open for 

more then 5 minutes.

Verify door is closed and 

sealing. Check reed switch 

and related connections.

Up

Select

Down

WELCOME TO THE

CUSTOMER MENU. USE

UP/DOWN ARROWS TO

SCROLL SETTINGS.

Summary of Contents for U-3090WCWCOL-00

Page 1: ...COM SERVICE MANUAL MODULAR 3000 SERIES 230V 3090 MODELS U 3090WCWCOL 00 U 3090WCWCS 00 The American Built In Undercounter Leader Since 1962 ALL MODULAR 3000 MODELS ARE INTENDED FOR BUILT IN INSTALLATI...

Page 2: ...he product installation and any alleged property damage 2 Inquire when the problem first appeared any prior problems with the product and provide a brief description of the alleged damages 3 To expedi...

Page 3: ...Select Control 6 Adjusting Temperature Settings 6 Interior Lighting 7 Error Notification 7 Customer Menu 7 Service Menu 9 USB Communication 14 Quick Guide 18 Convection Cooling 20 3000 Series Mainten...

Page 4: ...y your old refrigerator or freezer take off the doors and leave shelves in place so children may not easily climb inside This appliance is not intended for use by persons including children with reduc...

Page 5: ...trip base fascia is free of obstruction Obstructing free airflow can cause the unit to malfunction and will void the warranty Failure to clean the condenser every six months can cause the unit to malf...

Page 6: ...ne 7 C 13 C set point 10 C Red Wine 13 C 18 C set point 13 C Cabinet Configuration Model Door Configuration Left Zone Right Zone U 3090WCWCOL 00 Overlay Glass Doors Wine Racks Wine Racks U 3090WCWCS 0...

Page 7: ...following information on the Labor Invoice Name of the selling dealer Date of purchase installation Sales order or Invoice number Description of verification document i e Store Receipt Closing Papers...

Page 8: ...formation Thermistor Calibration While thermistors generally do not require calibration over time contact corrosion and or element wear may make calibration necessary Calibration To calibrate a thermi...

Page 9: ...h Mode and temperature ranges Mode selection will vary by model The 3090 Models have two independently controlled zones Each zone may have its own Mode and set point 1 In order to adjust set points yo...

Page 10: ...Should the system detect a fault an error notification will be displayed on the user interface See below for a list of errors Customer Menu The 3000 Series of U Line undercounter refrigeration applia...

Page 11: ...Sabbath mode disables system responses to user initiated activities and all external functions including lighting display and audible alarms The unit will still maintain internal temperatures and set...

Page 12: ...toring while settings are restored When restoration is complete Restoring will return to Restore To exit Factory Default use Up to select Return to Menu and press Select to confirm Help To access the...

Page 13: ...r circuit shorted Check connection Replace if necessary R Zone T Short Right Zone thermistor circuit shorted Check display cable Replace if necessary L Evap T Short Left evaporator thermistor circuit...

Page 14: ...h available information To exit the Input Status menu use Up to select Return to Menu and press Select to confirm Outputs Outputs is used to monitor the state of DC outputs To access Outputs 1 Use Dow...

Page 15: ...ic report Any system faults will be displayed under Self test If no errors are present no errors will be displayed and the main control board is functioning properly The main control board is extremel...

Page 16: ...Restore will change to Restoring while settings are restored When restoration is complete Restoring will return to Restore To exit Factory Default use Up to select Return to Menu and press Select to c...

Page 17: ...ly insert a flash disk in to the USB port located above the grille The flash disk activity light located on the flash disk will begin flashing immediately as data is recorded to the drive Data is reco...

Page 18: ...unning the cooling system To toggle showroom mode 1 Use Down to select Showroom Mode 2 Press Select 3 Use Down to select Off and press Select Off will begin to flash 4 Press Up or Down to toggle betwe...

Page 19: ...Differential Right Zone Offset Right Evap Offset L Door Indicator R Door Indicator Relay 1 Indicator Sample Data 0 0 Beverage 34 1 0 0 Field 21 22 23 24 25 26 27 28 29 30 ID Relay 2 Indicator Relay 3...

Page 20: ...C 30 Left LED intensity provided in 10 Left Zone Differential value in F C 31 Right LED intensity provided in 11 Left Zone offset value in F C 32 Energy Saver mode indicator E active 12 Left evaporat...

Page 21: ...ADJUST MODES PRESS AND RELEASE TO SCROLL THROUGH THE MODES 4 3090 ADJUST TEMPERATURE PRESS TO SELECT ZONE PRESS TO SET THE TEMPERATURE 3045 3060 ADJUST TEMP PRESS TO SET THE TEMPERATURE 5 3090 ADJUST...

Page 22: ...H AND RELEASE TO EXIT SERVICE MODE CONFIGURES THE ON BOARD USB PORT FOR FLASH DRIVE OR PC LINK DISPLAYS THE NUMBER OF TIMES AN ERROR HAS OCCURRED SCROLL TO THE END TO ERASE THE ERROR CODES DISPLAYS TH...

Page 23: ...order to operate efficiently the evaporator fan blade and vents should be unobstructed and free of any dust buildup Evaporator Fan Replacement Should the evaporator fan need to be replaced follow the...

Page 24: ...grille lock screws See below 3 Gently pull grille away from unit until it stops 4 Push grille rails towards the center of the unit to lift rails off lock screws 5 Pull grille free from unit Installin...

Page 25: ...over extend or damage it during door alignment Overlay Models Removing Overlay 1 Open door completely 2 Remove gasket 3 Remove six screws seated in gasket pocket Stainless Models Removing Wrap 1 Open...

Page 26: ...ivate with the switching of the relay If it does not see Component Testing on page 24 Inputs The main control monitors a number of thermistor inputs and switch states during operation It would be unli...

Page 27: ...ator fan is used Condition Customer complains of the unit not cooling properly The main screen of the display lists an error L Temp Hi 12H The compressor seems to be functioning properly however the l...

Page 28: ...oblem Airflow through the grill below the door in front cannot be obstructed Also the unit cannot be installed behind a closed door or in a closet The unit is too cold or freezing product Control set...

Page 29: ...er to Quick Chill Section of this manual Control set too cold Refer to Adjusting Temperature Settings Section of this manual Review logged error codes Refer to Fault System Diagnosis Guide Section of...

Page 30: ...ine to the compressor inlet The compressor takes the low pressure vapor and compresses it increasing both pressure and temperature The hot high pressure gas is pumped out the discharge line and into t...

Page 31: ...orce pulls the reed to its contact and closes the circuit which turns the light and display off When the door is open the reed pulls away from the contact and opens the circuit If the door s are left...

Page 32: ...s or damage Repair split or pinched cabling Amb Thrm Short Inspect thermistor cable for pinch points or damage Replace if necessary Inspect wire harness from main control board for pinch points or dam...

Page 33: ...ere no clear guidelines or solutions are evident today The newest Uihlein generation continues to build upon the family s innovative legacy at the Milwaukee Wisconsin based business by providing conti...

Reviews: