58
58
Rev08/04/2015
ALARM: ELECTRICAL FEEDING
It means that the voltage supply is not within the safety range. The range is
determined by parameter MRV Main Reference Voltage, plus or minus 20%.
Check the voltage actual reading from the Energy section during a cycle for
more details (2.4. Cycle Graph and other functions). Call Service if there is
suspect of low or high voltage.
ALARM: LOW TEMPERATURE
It occurs when during the holding cycle the air temperature goes below the
lower temperature limit, parameter ALL. This parameter is a differential respect
to the setpoint.
ALARM: HIGH TEMPERATURE
It occurs when during the holding cycle the air temperature goes above the
higher temperature limit, parameter ALH. This parameter is a differential
respect to the setpoint.
ALARM: AIR PROBE (S1)
Air probe failure. Call Service.
ALARM: EVAPORATOR PROBE (S2)
Evaporator probe failure. Call Service.
ALARM: CONDENSER PROBE (S3)
(Not applicable in this version of Blast
Chiller)
Condenser probe failure. Call Service.
ALARM: FOOD PROBE (PT1)
Insert probe core 1 failure. Call Service.
ALARM: FOOD PROBE (PT2)
Insert probe core 2 failure. Call Service.
ALARM: FOOD PROBE (PT3)
Insert probe core 3 failure. Call Service.