Door Adjustments

HINGE COVER

Hinge cover included with the literature bag is optional.

To install hinge cover:

1.  Press hinge cover squarely over hinge.

DOOR ALIGNMENT AND ADJUSTMENT

Align and adjust the door if it is not level or is not sealing 
properly. If the door is not sealed, the unit may not cool 
properly, or excessive frost may form in the interior.

NOTICE
Properly aligned, the door’s gasket should be 
firmly in contact with the cabinet all the way 
around the door (no gaps). Carefully examine the 
door’s gasket to ensure that it is firmly in contact 
with the cabinet. Also make sure the door gasket 
is not pinched on the hinge side of the door.

To align and adjust the door:

1. 

Gently pry off hinge cover from top of unit.

2. 

Loosen (do not remove) top and bottom hinge screws 
using a Torx T-25 screwdriver.

3.  Align door squarely with cabinet.

4. 

Make sure gasket is firmly in contact with cabinet all 

the way around the door (no gaps).

5.  Tighten bottom hinge screws.

6.  Tighten top hinge screws and replace hinge cover.

REVERSING THE DOOR

Location of the unit may make it desirable to mount the 

door on the opposite side of the cabinet.

The hinge hardware will be removed and reinstalled on the 
opposite side of the cabinet.

TO REVERSE THE DOOR

Remove grille:

Remove the grille (see GRILLE INSTALLATION section of 

this guide).

Remove top hinge and door:

1.  Hold door to keep it from falling.
2. 

Remove top hinge from cabinet using a Torx T-25 

screwdriver to remove three screws. Set aside and 
save for possible future use.

Hinge Cover

9

Summary of Contents for UCNP115

Page 1: ...QUICK START GUIDE 30657_B ICE UCNP115 15 NUGGET ICE MACHINE...

Page 2: ...consin USA and select products are available worldwide PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Product...

Page 3: ...your product For more details see the complete User Guide Service Manual on u line com CONTENTS Safety and Warning 4 Environmental Requirements 5 Electrical 5 Water Hookup 5 Drain 7 Door Swing 8 Door...

Page 4: ...r use Do not use sharp objects to expedite defrosting Do not service without consulting the R600a specifications section included in the User Guide Do not damage the refrigerant circuit Service must b...

Page 5: ...Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has been plac...

Page 6: ...pressure at all times Plastic may crack or rupture with age and cause damage to your home Do not use tape or joint compound when attaching a braided flexible water supply line that includes a rubber g...

Page 7: ...is to be installed with adequate backflow protection to comply with applicable federal state and local codes Model numbers including CL or NB do not include a factory installed drain pump Model numbe...

Page 8: ...ter Waste Shut O Valve Disposal Assembly P60 Pump Required Waste Cold Water Shut O Valve Hot Water Air Gap Optional Hook Up Y Branch Tailpiece P60 Pump Required 21 21 16 1 2 16 1 2 90 Door Swing 90 Do...

Page 9: ...or To align and adjust the door 1 Gently pry off hinge cover from top of unit 2 Loosen do not remove top and bottom hinge screws using a Torx T 25 screwdriver 3 Align door squarely with cabinet 4 Make...

Page 10: ...Replace nuts if used Prepare door for reinstallation 1 Remove gasket This will reveal mounting holes for the magnet assembly 2 Remove magnet assembly from door with T 10 TORX driver Be sure to only re...

Page 11: ...otal unit rear height of 1 8 3 mm less than opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust th...

Page 12: ...fied See www star k org for more details DOOR ALERT NOTIFICATION When the door is left open for more than 30 minutes Ice production will cease A tone will sound for several seconds every minute will a...

Page 13: ...r Comparable products are acceptable Frequent cleaning will remove surface contamination that could lead to rust Some installations may require cleaning weekly Cleaning Do not clean with steel wool pa...

Page 14: ...hine Poor ice quality and reduced ice output are signs that cleaning is necessary Under normal conditions cleaning should be done when the display shows CL You may initiate a cleaning cycle at any tim...

Page 15: ...d cleaning tube slowly pour 3 4 of the cleaning solution into the dispenser tube Air and some water will exit the vent tube Remove cleaning tube Optional for deeper cleaning allow solution to soak for...

Page 16: ...d or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guide The remedies described above for each warranty are the only ones that U...

Reviews: