background image

Copyrigh

U-Line Corporation. All Rights Reserved. |  Publication Number 30379 |  

1

1

/20

2

2

 Rev. 

P

 

U-Line Corporation (U-Line) Limited Warranty

One Year Limited Warranty 

For one year from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of the product that 
proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects 
are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the 
above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service provided during 
normal business hours.  

Two Year Limited Warranty (5 Class Product) 

For two years from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of the product that 
proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects 
are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the 
above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service provided during 
normal business hours. 

Available Second & Third Year Limited Warranty 

In addition to the standard one and two year warranties outlined above, U-Line offers a one year extension of the warranties from the date 
of purchase, free of charge. To take advantage of this extension, you must register your product with U-Line within 60 days from the date 
of purchase at u-line.com and provide proof of purchase.

 Nugget Ice Machine proof of purchase must include the purchase of an in-line 

water filter and filter head to qualify for this additional limited warranty.

 

Five Year Sealed System Limited Warranty 

For five years from the date of original purchase, U-Line will repair or replace the following parts, labor not included, that prove to be 
defective in materials or workmanship: compressor, condenser, evaporator, drier, and all connecting tubing. All service provided by U-Line 
under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service 
provided during normal business hours. 

Terms 

These warranties apply only to products installed in any one of the fifty states of the United States, the District of Columbia, or the ten 
provinces of Canada. The warranties do not cover any parts or labor to correct any defect caused by negligence, accident or improper use, 
maintenance, installation, service, repair, acts of God, fire, flood or other natural disasters. The product must be installed, operated, and 
maintained in accordance with your product’s User Guide. 

The remedies described above for each warranty are the only ones that U-Line will provide, either under these warranties or under any 
warranty arising by operation of law. U-Line will not be responsible for any consequential or incidental damages arising from the breach of 
these warranties or any other warranty, whether express, implied, or statutory. Some states do not allow the exclusion or limitation of 
incidental or consequential damages, so the above limitation or exclusion may not apply to you. These warranties give you specific legal 
rights, and you may also have other rights which vary from state to state.   

Any warranty that may be implied in connection with your purchase or use of the product, including any warranty of 

merchantability 

or any 

warranty 

fit for a particular purpose

 is limited to the duration of these warranties, and only extends to five years in duration for the parts 

described in the section related to the five year limited warranty above. Some states do not allow limitations on how long an implied warranty 
lasts, so the above limitations may not apply to you. 

The warranties only apply to the original purchaser and are non-transferable.

The second, third, and five year warranties cover products installed and used for normal residential or designated marine use only.

The warranties apply to units operated outside only if designed for outdoor use by model and serial number.

U-Line Commercial products are covered by the one year and 5 year limited warranties and are not eligible for the second and
third year limited warranties.

Replacement water filters, light bulbs, and other consumable parts are not covered by these warranties.

The start of U-Line’s obligation is limited to four years after the shipment date from U-Line.

In-home instruction on how to use your product is not covered by these warranties.

Food, beverage, and medicine loss are not covered by these warranties.

If the product is located in an area where U-Line factory authorized service is not available, you may be responsible for a trip
charge or you may be required to bring the product to a U-Line factory authorized service location at your own cost and expense.

Units purchased after use as floor displays, and/or certified reconditioned units, are covered by the limited one year warranty only
and no coverage is provided for cosmetic defects.

Signal issues related to Wi-Fi connectivity are not covered by these warranties.

For parts and service assistance, or to find U-Line factory authorized service near you, contact U-Line: 

8900 N. 55

th

 

Street, Milwaukee, WI 53223 • u

-

line.com • onlineservice@u

-

line.com • +1.

414

.

354

.

0300

 

47

Summary of Contents for UOCR115-SS01A

Page 1: ...USER GUIDE SERVICE MANUAL Model UOCR115 SS01A...

Page 2: ...nstallation Water Hookup Anti Tip Bracket General Installation Grille Installation Door Swing Door Adjust Maintenance Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use Ice...

Page 3: ...HT PRODUCT RIGHT PLACE RIGHT TEMPERATURE PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings and Product Warranty information are available digi...

Page 4: ...statement will result in severe personal injury or death Warning means that failure to follow this safety statement could result in serious personal injury or death Caution means that failure to foll...

Page 5: ...e so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of refriger...

Page 6: ...uce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat generating equipment In climates where high humidity and dew points are present con...

Page 7: ...it Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has been pl...

Page 8: ...e rear CAUTION Unit can NOT be installed behind a closed cabinet door CUTOUT DIMENSIONS 15 cutout width sufficient if door protrudes beyond adjacent cabinetry PRODUCT DIMENSIONS REAR 24 610 mm 1 1 2 3...

Page 9: ...cording to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are easily accessible 2 Remove screws as shown bel...

Page 10: ...ater line should be looped into 2 coils This will allow the unit to be removed for cleaning and servicing Make certain that the tubing is not pinched or damaged during installation WARNING Connect to...

Page 11: ...r feature in bushing with flat screwdriver 5 Thread water line through back panel hole with bushing 6 Locate water valve inlet and connect to valve 7 Turn on water supply and check for leaks 8 Reinsta...

Page 12: ...oles and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighten screws fully 4 Gently push unit into position Be careful not to entangle the electrical cord or water line if...

Page 13: ...ing s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the unit after it is corre...

Page 14: ...nit the grille must be installed Removing the grille 1 Disconnect power to the unit 2 Remove three screws 1 3 Slide grille 2 away from bottom hinge and remove grille from unit Installing the grille 1...

Page 15: ...its have a zero clearance for the door to open 90 when installed adjacent to cabinets Stainless Steel models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wall Wa...

Page 16: ...top of unit 2 Loosen do not remove top and bottom hinge screws using a Torx T 25 screwdriver on the top and a 1 4 socket on the bottom 3 Align door squarely with cabinet 4 Make sure gasket is firmly...

Page 17: ...ng outward exposing the gasket channel 3 Remove the 3 pieces of gasket channel filler and reinstall on the opposite end of door 4 Install gasket into channel beginning at one corner and pressing in fi...

Page 18: ...recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may dislodge from the water line To turn the unit on or off Press the rock...

Page 19: ...ration You may hear the compressor or fan motor the water valve or ice dropping into the ice bucket CAUTION NEVER use an ice pick knife or other sharp instrument to separate cubes Shake the ice bucket...

Page 20: ...an adjustment to the screw can cause the water to overflow the ice maker and can cause property damage 3 Turn the adjusting screw toward the minus sign clockwise for smaller cubes or toward the plus s...

Page 21: ...ding Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency Do not block the front grille at any time or the unit will not perform as expected Do not...

Page 22: ...lorine glass cleaner Do not use cleaners not specifically intended for stainless steel on stainless surfaces this includes glass tile and counter cleaners If any surface discoloring or rusting appears...

Page 23: ...rd ice 3 Place towel or other absorbent material on bottom of ice bin 4 Fill the ice bucket half full with warm not hot water This will help the unit defrost faster 5 Place the ice bucket back into th...

Page 24: ...ning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser WARNING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged NOTICE...

Page 25: ...st remain open to prevent formation of mold and mildew Open door a minimum of 2 50 mm to provide the necessary ventilation WINTERIZATION If the unit will be exposed to temperatures of 40 F 5 C or less...

Page 26: ...listed Compressor The compressor makes a hum or pulsing sound that may be heard when it operates BEFORE CALLING FOR SERVICE TROUBLESHOOTING GUIDE ELECTROCUTION HAZARD Never attempt to repair or perfo...

Page 27: ...CAM 3 RPM MOTOR LIMIT SW MOLD HEATER YELLOW RED WHITE BROWN BLACK RED Y E L L O W BROWN BLACK BROWN O R A N G E O R B L U E BLACK OR BLUE OR ALL OTHER MODELS ICEMAKER BI1215 ONLY CONTROL GROUND GREEN...

Page 28: ...replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial number of the unit it was removed from the dat...

Page 29: ...r warranty labor Units must be registered prior to warranty submittal Customers may register at www U Line com A proof of purchase is required We also accept the following information to update warran...

Page 30: ...NOB 80 54382 00 10 DOOR ASSEMBLY 80 55549 00 11 DRIER 80 54055 00 12 EVAP CABINET ASSEMBLY 80 54397 00 13 FACEPLATE 115V 80 54523 00 14 FRONT PANEL 80 55472 00 15 GASKET DOOR 80 55428 00 16 GRILLE 80...

Page 31: ...ranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U Line requires the return of original parts we will inform...

Page 32: ...mely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near room temperature Very hot Top passes warm Lower passes cool near ro...

Page 33: ...e power source Do not stand in standing water when working around electrical appliances Make sure the surfaces you touch are not ho All resistance readings are 10 EM150HER Refrigerant R134a Voltage 11...

Page 34: ...switch Bin arm binding Lubricate bin arm pivot points or loosen bin arm lever screw Water will not stop filling Water switch inoperable closed Replace water switch Solenoid valve inoperable Replace so...

Page 35: ...drain pan Position drain line in drain pan Crack in water line Replace water line Water leak inside unit Ice maker assembly fill cup obstructed Remove obstruction Fill ice cup and fill tube out of al...

Page 36: ...Failure Water Adjustment Bin Switch Failure NO NO EVERYWHERE INTERMITTENT AT 3 00 YES NO AT 12 00 DOES THE UNIT HARVEST ICE IF THE EJECTOR BLADES ARE MOVED BY HAND OR WITH A WRENCH WHERE DO THE EJECT...

Page 37: ...wer to the condenser fan Figure 1 Freeze Cycle SWITCH LIMIT orange black black black MOTOR MAKER ICE MOLD HEATER WATER SWITCH FILL C NC MOTOR FAN LOAD OVER black RELAY START COMP SWITCH OFF ON black b...

Page 38: ...maker motor If bin arm is up the ice maker will not harvest Figure 2 Harvest 1 Cycle Hold Switch in Normal Position SWITCH LIMIT orange black black black MOTOR MAKER ICE MOLD HEATER WATER SWITCH FILL...

Page 39: ...on ice and ice maker motor pulsates until mold heater warms and ice releases Figure 3 Harvest 2 Cycle Hold Switch in Switched Position SWITCH LIMIT orange black black black MOTOR MAKER ICE MOLD HEATE...

Page 40: ...and stop at 12 00 position Temperature control terminals 2 and 3 have closed during harvest cycle Next freeze cycle begins with power to the compressor and condenser fan SWITCH LIMIT orange black blac...

Page 41: ...3 contacts open stopping the compressor and the 2 1 contacts are closed starting the ice maker motor The 2 3 contacts close 2 1 contacts open before the end of the ice harvest cycle The hold switch p...

Page 42: ...83 F The function of this switch is to open in the event of an overheating condition This bi metal thermostat is normally closed and does not initiate the ice harvest cycle The ice harvest cycle is in...

Page 43: ...ejector blade to the 3 o clock position by turning the 5 16 hex head on the small brass gear counterclockwise 4 7 Remove three screws from wall of freezer housing 5 8 Remove ice maker assembly 9 Place...

Page 44: ...h alumilastic to heater side of new ice maker 12 Replace parts in reverse order of removal 13 Reconnect all wires 14 Insert capillary tube into ice maker sensing tube 15 Insert water inlet tube 16 App...

Page 45: ...ior walls Frost will build up faster in humid environments and when the door is opened frequently To defrost remove ice bucket turn off unit leave door open and allow frost ice to melt naturally Do no...

Page 46: ...wire harness at plug 3 Disconnect thermistor plug 4 Remove water inlet tube 5 Remove front cover 6 Advance ejector blade to the 3 o clock position by turning the 5 16 hex head on the small brass gear...

Page 47: ...improper use maintenance installation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guid...

Reviews: