USER GUIDE
Remove Fan and Cover
Remove Fan and Cover
FREEZER
CONVECTION COOLING
This unit is equipped with an advanced convection cooling
system. Convection cooling stabilizes cabinet temperature,
cools product faster, and increases energy efficiency.
Evaporator Fan
The evaporator fan is responsible for circulating warm air
from the refrigeration zone, past the evaporator and back
into the refrigerated zone.
The evaporator fan is factory set to have a 1 minute delay
at the beginning of a cooling cycle. This delay gives the
evaporator time to cool properly before warm air is passed
over it. The fan will continue to run for an additional 2
minutes at the end of a cooling cycle. Fan delay times can
be modified through the service menu.
Evaporator fan operation is also determined by door switch
state. If the door switch circuit opens, the fan will stop.
When the door switch circuit is closed the fan will either
continue running with the cooling cycle, or if not currently
cooling, the fan will run for 1 minute to circulate air.
Note:
If the unit is set to sabbath mode, the evaporator
fan will no longer respond to the state of the door switch.
In order to operate efficiently, the evaporator fan blade
and vents should be unobstructed and free of any dust
buildup.
Evaporator Fan Replacement
Should the evaporator fan need to be replaced follow the
steps below.
1. Remove any product from the unit.
2.
Turn off the unit.
3. Remove 2 evaporator cover screws in the ceiling of the
unit. (See Figure 1)
Figure 1: Remove 2 Screws
4. Grasp evaporator cover and pull forward far enough to
see behind the fan and unplug the fan. Then remove
entire evaporator cover assembly.
5. The fan and fan guard are held to the evaporator
cover with four screws. Remove the four screws held
in place by four
lock washers
and four nuts.
(See Figure 2)
Figure 2: Remove Fan Assembly from Evaporator Cover
NOTICE
Fan must be oriented to pull air in through lower
evaporator cover vents and push air out at fan
mounting location.
6. Installation is the reverse of removal.
Remove 2 Screws
Air F
low
Power Lead
47