background image

U-Line Electrical / Plumbing Specfications

13

1. Plug in the power cord.

2. Open the top drawer and press the 

POWER

 icon to turn the 

unit 

OFF

.

3.

C2275DWR Only:

 

Open the water supply valve in the main 

water source.

4. Gently push the unit into position. Be careful not to entangle the 

electrical cord. 

5. Re-check the leveling, from front to back and side to side. Make 

any necessary adjustments. The unit’s top surface should be 
approximately 1/8" below the countertop.

Anti-Tip Kit Installation

WARNING

• The Anti-Tip Kit must be installed on this unit before 

it is used. 

• Additional blocking or special fasteners may be 

required for installation. Installer is responsible for 
secure attachment to prevent the unit from tipping.

• Make sure the mounting screws attaching the unit to 

the counter, cabinet or wall are deep enough into the 
mounting surface to support the weight of the 
drawers and the items that will be inside the drawers.

• Never use the drawers as steps or as a shelf to 

support more than the drawers’ content. Serious 
personal injury could occur.

After leveling, the unit must be secured to a counter, a cabinet or a 
wall to prevent tipping.

1. Open the upper drawer to expose the six screws (A) installed 

at the top two corners (three at each corner). Remove the 
appropriate screws for horizontal or vertical mounting Do not 
discard.

2. Insert the screws through the anti-tip bracket (B) and attach the 

bracket to the unit. Tighten screws securely.

3. Repeat for the other side.

Note: 

The bracket should be flush with the surface it is being 

attached to. If it is not, loosen the screws and slide the bracket 

against the mounting surface. Tighten screws securely.

4. Using two of the screws (C) supplied, fasten the screws through 

the bracket and into the counter, cabinet or wall.

IMPORTANT

IMPORTANT

Certain cabinets or countertops may require special 
fasteners or additional wood blocking to anchor properly.

CAUTION

Make sure the screws are back far enough so they do not 

damage any exposed front surface of the cabinet.

Installation Troubleshooting

Problem

Q:

The drawer remains open unless it is pushed closed.

Solution

A:

The drawer should be self-closing when it is open approximately 
8". If it is not, re-check leveling from front to back of the unit and 
readjust if necessary. 

Problem

Q:

Water is leaking under the unit (C2275DWR units)

Solution

A:

A water leak under the unit is most likely caused by a bad 
connection in the water supply line. Make sure the water line’s 
brass fitting is screwed tight to its valve and threaded correctly.

11 Install Unit

A

B

Countertop or Wall Header

C

Cabinet or Wall Stud

A

C

B

Horizontal Mounting 
(Left Side Shown)

Vertical Mounting 
(Left Side Shown)

Summary of Contents for WINE CAPTAIN 2275DWRCOL

Page 1: ...t In Undercounter Leader Since 1962 2000 SERIES DRAWER MODELS REFRIGERATORS COMBO REFRIGERATOR FREEZER ICE MAKERS WINE CAPTAIN MODELS U LINE COM 2275DWRCOL C2275DWRS 2275DWRCS INSTALL GUIDE C2275DWROL...

Page 2: ...onmental Requirements 5 Standard Drawers Checking Drawer Alignment 6 Adjusting Drawer Alignment 6 Re installation of Drawer 7 Drawer Panel Installation Custom 1 4 Drawer Panel Inserts 8 Drawer Panel P...

Page 3: ...Grounding Required Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected Never remove the round grounding prong from the plug and never use a two prong...

Page 4: ...d If installing a 3 4 Full Overlay panel 3 4 overlay frame material Cutting Tools Drill Drill Bits If installing 1 4 Panel Insert 1 4 thick door panel material Cutting Tools Exterior Cleaning Overlay...

Page 5: ...polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch circuit or circuit breaker is recommended GFCI ground fault circuit interrupter is usually not...

Page 6: ...ck Stainless Steel 33 7 8 24 23 3 8 3 7 8 23 1 4 33 7 8 24 3 7 8 33 7 16 23 3 8 23 15 16 3 7 8 Stainless 2275DWRW C2275DWR 2275DWRC Black Stainless Steel 33 7 8 24 23 3 8 3 7 8 23 1 4 33 7 8 24 3 7 8...

Page 7: ...5A circuit normal household current See Electrical Specifications Water Supply The unit requires a 1 4 inch OD water supply line and a shut off valve For more information see Page 12 Environmental Req...

Page 8: ...the slides mounting screws drilling new mounting holes and remounting the slide Side to Side Adjustment The drawer will need a Side to Side Adjustment if when viewed from the top the drawer front is...

Page 9: ...oosen one slide s mounting screws 2 Push the slide upward or downward to match the position of the other slide 3 Retighten the screws 4 Repeat the procedure with the other slide if necessary Severe Ad...

Page 10: ...el insert into 1 4 inch channel in drawer front 6 Holding drawer gasket out of the way replace handle on drawer making sure it is seated properly on insert and that screw holes line up 7 Install two s...

Page 11: ...Attach the drawer panel to the overlay panel using 10 x 5 8 wood screws and nylon spacers The nylon spacers fit between the overlay panel and the door panel as shown in Figure 11 The spacers allow th...

Page 12: ...led in such a manner that the grille assembly can still be removed from the unit Screw Mount Recommended 1 Remove the grille from your unit by removing the two mounting screws See below 2 Lay the back...

Page 13: ...U Line Grill Overlay Installation 11 1 4 8 1 2 3 3 32 19 5 8 1 2 1 2 TYP 3X 5 16 TYP 2X 7 16 5 16 10 5 16 11 64 2 1 8 1 2 22 7 8 23 7 8 FULL R Grille Overlay Dimensions 24 Inch Models Grille Drawing...

Page 14: ...route the tubing to the appliance Leave approximately 8 of water line to be coiled behind the appliance The water line should be looped into 2 coils This will allow the line to flex when removing the...

Page 15: ...each corner Remove the appropriate screws for horizontal or vertical mounting Do not discard 2 Insert the screws through the anti tip bracket B and attach the bracket to the unit Tighten screws secure...

Page 16: ...ss and hold the POWER icon on the display panel for aproximately ten seconds until the F symbol flashes and release U Line recommends that the unit be allowed to run overnight prior to loading the ref...

Page 17: ...today The Milwaukee Wisconsin based family operated business provides continuity and vision from which innovations continue to be born Going forward U Line will continue offering best in class product...

Reviews: