24
Door contact connection
Panel has one terminal for door contact connection. Loop is normal when shorted
that means that door is closed and signals the door opening on breakage.
Normally panel supplied with Request-To-Exit and Door contact switched OFF. To use Door
contact install Request-To-Exit microswitch and turn Door contact supervision ON.
Panel defines the access point state with the door contact. It is impossible to detect
the door forced open or door opened too long access point states without the door
contact proper operation.
Panel generates the
“Entry occurred” message on inner handle press when the door
contact is absent.
To enable door contact
set the Z1 zone as ‘A’ door pass
direction detector.
Request-To-Exit contact connection
Normally panel supplied without
installed Request-To-Exit sensor.
In this case you must adjust
Request-To-Exit micro switch on
inner escutcheon according to
the figures below:
1.
Unscrew 4 screws fixing
handle release mechanics
(See Fig. 11)
2.
Install micro switch into the
correct position (See Fig. 12)
3.
Install
handle
release
mechanics back on its place.
Fig. 12.
Installing microswitch
unscrew
unscrew
Fig. 11.
Opening handle release mechanics