Chapter
➁
- Function Introduction
22
6.4.3.2 Big Random Data
A set of different random character to be written into a set of area.
This erase pattern method is safer for preventing from data recovered.
[Erase Pattern]
Big Random Data
26A5C8781
BF51337E81
AA9641D3B
5CDA756B1
3BAFF21FF4
1FBAC4C99
7EDAF1237
7F51C59C3
6.4.4 Wait HDD Time
You can select auto-start time after plugging in HDD, able to set the
waiting time from 0 to 30 seconds.
[Wait HDD Time]
15 seconds
6.4.5 Transfer Rate
You can select the best transfer rate from UDMA 2 to UDMA7 for your
HDD duplication process. If you are not confident on the HDD quality or
you find a high failure rate on copy or compare. It is recommended to
slow down the UDMA mode.
[Transfer Rate]
UDMA 5
6.4.6 Stop Motor Time
When the system finishes executing functions, the motor won’t stop
running immediately. This function is used to set the time of motor
stopping after finishing function executing from 1 to 20 seconds.
Summary of Contents for PRO368