background image

1

102142-04 - 8/19

Installation Instructions

MPO-IQ™ and EMP 

Direct Vent Conversion Kit

A.

 General.

 These instructions contain information to 

convert from the MPO-IQ and EMP to Direct Vent.

B.

  Materials provided 

with this kit.

1.  Direct Vent Kit (see Table 1 for Part Number)
2.  Installation Instructions 
3.  Conversion Label 
4.  Instruction Envelope Assembly  

5.  Direct Vent Clearance Label 

C.

  Removal of AFG Burner

.

1.  Unplug burner power cord from power outlet 

receptacle located in lower right corner of 

Front Jacket Panel.

2.  Remove three (3) 5/16” -18 x 3/4” long Cap 

Screws securing burner to Burner Swing Door.

3.  Remove oil burner from opening of Burner 

Swing Door.

D.

  Installation of NX Burner.

  Refer to Figure 1.

1.  Check oil nozzle in burner for size, angle and 

type, inspect electrode settings, check head 

setting, check air band and air shutter settings.  

Refer to Table 2 of this supplement.

2.  Place oil burner gasket on burner and align 

holes.

!

 CAUTION

      Do not install burner without gasket

3.  Thread (1) 5/16” -18 x 3/4” long cap screw, 

approximately three (3) full turns, into tapping 

located at 12:00 o’clock on burner swing door.

4.  Insert oil burner into opening of burner swing 

door.  Align and engage keyhole slot in burner 

flange over head of protruding cap screw 

installed in previous Step.  Rotate burner to the 

right to lock flange behind head of cap screw.

Description

Part No.

147/140

189/182 231/224

Direct Vent Kit Model FDVS-56

102130-02

1

1

---

Direct Vent Kit Model FDVS-67

102130-03

---

---

1

Figure 1:  Oil Burner Installation

Table 1:  Direct Vent Kit Part Numbers