38
107672-01 - 7/17
Option #
31
32
33
34
35
36
Illustrated in Figure
7.22
7.22
7.23, 7.24
7.23, 7.24
7.23, 7.24
7.23, 7.24
Pipe
Penetration
Through Wall
Vent
Roof
Roof
Roof
Roof
Roof
Roof
Intake
Wall
Wall
Wall
Wall
Wall
Wall
Material
Vent
Centrotherm
InnoFlue SW
Centrotherm
InnoFlue
SW
DuraVent
PolyPro
(Rigid/Flex)
DuraVent
PolyPro
(Rigid/Flex)
Selkirk Polyflue
(Rigid/Flex)
Selkirk Polyflue
(Rigid/Flex)
Intake
PVC
PVC
PVC
PVC
PVC
PVC
Nominal
Diameter
Vent
2”
3”
2”
3”
2”
3”
Intake
2” or 3”
3”
2” or 3”
3”
2” or 3”
3”
Min Equivalent Vent Length:
Models
080
48”
48”
48”
48”
48”
48”
100
48”
48”
48”
48”
48”
48”
120
Not
Permitted
48”
Not Permitted
48”
Not Permitted
48”
150
52”
52”
52”
180
52”
52”
52”
Max Equivalent Vent Length (Note 1):
Models
080
60ft
135ft
60ft
135ft
60ft
135ft
100
60ft
135ft
60ft
135ft
60ft
135ft
120
Not
Permitted
135ft
Not Permitted
135ft
Not Permitted
135ft
150
135ft
135ft
135ft
180
135ft
135ft
135ft
Rigid Vent
Terminals
Vent
ISEP02 or
ISEP0239 w/
Screen
ISEP03 or
ISEP0339
w/Screen
Not Permitted
Intake
90 Elbow w/
Screen
90 Elbow w/
Screen
Flex
Termination &
Components
(Masonry
Chimney
Chase) (Note
3)
Vent
Not Permitted
2PPS-FK
2PPS-FLEX**
3PPS-FK
3PPS-FLEX**
2PF-FLEX-KIT
2PF-FLEX
3PF-FLEX-KIT
3PF-FLEX
Intake
90 Elbow
w/Screen
90 Elbow
w/Screen
90 Elbow
w/Screen
90 Elbow
w/Screen
Flex
Termination &
Components
(B-Vent
Chimney
Chase)
Vent
Not Permitted
2PPS-VFT
2PPS-BF*
2PPS-FLEX**
3PPS-VFT
3PPS-BF*
3PPS-FLEX**
2PF-10UV or
2PF-39UV
w/Screen
2PF-BVSC
(Note 3)
3PF-10UV or
3PF-39UV
w/Screen
3PF-BVSC
(Note 3)
Intake
90 Elbow
w/Screen
90 Elbow
w/Screen
90 Elbow
w/Screen
90 Elbow
w/Screen
VII. Venting
D. Design Requirements Unique to Split Vent Systems (continued)
Table 7.21: Summary of Split Vent System Options (cont.)
* Specify size of B vent (e.g. 2PPS-BV6 is for use with 6” B vent).
** Specify length in feet.
**** Specify Flex length and B vent diameter (e.g. IFBK022505 includes 25ft of flex and used with 5” B vent).
Note 1: Max vent lengths shown also apply to the intake. Flex vent reduces the maximum allowable vent length in some
applications. See equivalent lengths for flex vent shown in Table 7.14 and sizing example on page 35.
Note 2: First 30” plus first exhaust elbow are CPVC.
Note 3: See vent manufacturer’s installation manual for gaskets, spacers and other required vent compone
nts
All vertical terminals require compatible roof flashing and storm collars.
Summary of Contents for K2WT-080B
Page 83: ...83 107672 01 7 17 PAGE LEFT INTENTIONALLY BLANK...
Page 89: ...89 107672 01 7 17 X Wiring continued Figure 10 5 Internal Ladder Diagram...
Page 90: ...90 107672 01 7 17 X Wiring continued...
Page 91: ...91 107672 01 7 17 Figure 10 6 Internal Wiring Connections Diagram X Wiring continued...
Page 102: ...102 107672 01 7 17 Lighting and Operating Instructions XI Start Up and Checkout continued...
Page 147: ...147 107672 01 7 17 XV Service Parts continued...
Page 151: ...151 107672 01 7 17 XV Service Parts continued...
Page 153: ...153 107672 01 7 17 XV Service Parts continued 85 86 91 95...
Page 162: ...162 107672 01 7 17...
Page 163: ...163 107672 01 7 17...
Page 164: ...164 107672 01 7 17...
Page 165: ...165 107672 01 7 17...
Page 166: ...166 107672 01 7 17...
Page 167: ...167 107672 01 7 17...