This screen shows the XS1000’s current status. All of the 

information provided is read-only.   

Kernel Version: the installed version of the kernel.   

MAC Address: The present device MAC Address. 

Nickname: 

the product’s NetUART model name. 

   

 

 

5.0 Load default setting 

Allows  the user  to reset  the  XS1000  to  default settings. The 

MAC Address will not be updated. 

 

 

5.1  Telnet 

Currently not supported. 

5.2 Operation mode   

The XS1000 supports four operation modes: TCP Server, 

TCP Client, UDP Server and UDP Client. These modes 

are listed in the Web page for the Operation Mode setting. 

Each setup screen and available features will differ 

depending on what kind of operation mode you select. 

Default is TCP Server.   

5.3 

TCP Server 

 

Port Number:

 default 

23

, range 

0

 to 

65535

   

If your device is acting as a passive device to accept 

commands from a remote device and the data needs to be 

guaranteed to be received by the peer is your concern, then 

you can set the XS1000 as TCP 

U

Server

U

. Be sure the value of 

the setting

 Port Number

 is same as your remote control 

application using.     

Client mode inactive timeout 

(minutes):

 default 

20 

(

 0=Disable) 

If you want to keep the connection between XS1000 and your 

remote control application always on, then set the value of item 

Client mode inactive timeout 

(minutes) 

to 0, otherwise, 

when the inactive time of ‘no traffic’ on the line reach the 

configured value, the XS1000 will terminate the connection.   

5.4 TCP Client 

 

Remote Connection Port Number:

 default 

23

, range 

0

 to 

65535

   

Remote Host IP Address:

 default 

210.200.181.102

   

If your device is acting as an active device to report real-time 

status to remote devices and the data needs to be guaranteed 

to be received by the peer is your concern, then you can set the 

XS1000 as TCP 

U

Client

U

. Be sure the value of the setting 

Remote

 

Connection Port Number

 is same as your remote 

control application using the correct value of 

Remote Host IP 

Address

.   

5.5 UDP Server 

 

Local Port Number:

 default 

21

, range

 0

 to 

65535

   

If your device is acting as a passive device to accept 

commands from a remote device and the data needs to 

be guaranteed to be received by peer is 

not

 your concern, 

then you can set XS1000 as UDP Server. Be sure the 

value of item 

Local Port Number

 is same as what your 

remote application is using.   

5.6 UDP Client 

 

Remote Connection Port Number:

 default 

21

, range 

0

 to 

65535

   

Remote Host IP Address:

 default 192.168.2.2 

If your device is acting as an active device to report 

real-time status to a remote device and the data be 

guaranteed to be received by the peer is 

not

 your 

concern, then you can set XS1000 as TCP Client. Be 

sure the value of item 

Remote

 

Connection Port 

Number

 is same as your remote control application 

using the correct value of 

Remote Host IP Address

 

 

6.0

 

UART Control (RS-232)

 

Use VCOM for creating a new COM port.   

The XS1000 support three serial types: RS232, RS422 and 

RS485.   

Baud Rate: default 57600, range 300bps to 230.4Kbps.   

Character Bits: 5, 6, 7, 8 (default).   

Parity Check: None (default), even, odd, space, mark. 

Stop Bits: 1 (default), 1.5 or 2.   

Hardware Flow Control: None (default) or Hardware. 