TYPICAL INSTALLATION

MOUNTING

(New Frame Construction)

CEILING

JOIST

(24”

centers
shown)

12” ROUND

DUCT

(OUTLET)

ACCESS

PANEL

Factory-shipped unit installed in new construction.

MOUNTING

SCREWS

ACCESS

PANEL SCREW

Ventilator factory-

shipped

in straight-through

discharge position.

MOUNTING
BRACKETS

MOUNTING

(Existing Frame Construction)

Factory-shipped unit installed in existing construction.

TYPICAL INSTALLATION

WIRING

WIRING

PLATE

WHITE

TO

WHITE

BLACK

TO

BLACK

EDGE

OF HOUSING

120 VAC LINE IN

GROUND TO

WIRING PLATE

ACCESS

PANEL

SCREW

DUCTING

(Straight-through blower discharge)

Two ways to connect ductwork to a factory-shipped unit.

Ventilator can be wired from outside of housing.

Use UL approved connectors to wire per local codes.

ROOF CAP

12” ROUND

ELBOW

12”

ROUND

DUCT

WALL

CAP

IMPORTANT:
Remove shipping tape from damper

Remove the shipping tape from the damper flap and make sure
that damper flap opens and closes freely inside the ductwork. Use
duct tape to make ductwork connections secure and air-tight.

8” X 12”

TO

12” ROUND

TRANSITIONS

8” X 12” TO 12” ROUND

TRANSITIONS

12” ROUND DUCT

(OUTLET)

FINISHED

CEILING

MATERIAL

Ventilator

factory-shipped

in straight-through

discharge position.

MOUNTING
BRACKETS

8” X 12” TO

12” ROUND

TRANSITIONS

CEILING

JOIST

(24” centers

shown)

ACCESS PANEL

12” ROUND

DUCT

(INTAKE)

12” ROUND

DUCT (INTAKE)

12”

ROUND

DUCT

GRILLE NUT

(Install into square

holes in housing)

GRILLE NUT

(Install into

square holes in

housing)