IMPORTANT SAFETY INSTRUCTIONS

This machine is only suitable for commercial use, for example in hotels, schools, hospitals, factories, shops and
offices other than normal residential housekeeping purposes.

When using any electrical appliance, basic precautions should always be followed, including the following:

NOTE: Read all instructions before using this machine.

WARNING!

To reduce the risk of fire, electric shock, or injury:

• Do not leave the machine unattended when it is plugged in.  Unplug the unit from the outlet when not

in use and before servicing.

• To avoid electric shock, do not expose to rain or snow.  Store, and use, indoors.

• Do not allow to be used as a toy.  Close attention is necessary when used near children.

• Use only as described in this manual.  Use only the manufacturer’s recommended attachments.

• Never add water over 130º F/54º C to the solution tank.

• Do not use with damaged cord or plug.  If the machine is not working as it should, has been dropped,

damaged, left outdoors or dropped into water, return it to a service center.

• Do not pull by the cord, use the cord as a handle, close a door on the cord, or pull the cord around sharp

edges or corners.  Do not run the machine over the cord.  Keep the cord away from heated surfaces. To
unplug, grasp the plug, not the cord.

• Do not handle the plug, the cord or the machine with wet hands.

• Extension cords must be 12/3 and no longer than 50 feet.  Replace the cord or unplug immediately if the

ground prong becomes damaged.

• Do not put any object into openings.  Do not use with any opening blocked; keep free of dust, lint, hair,

and anything that may reduce air flow.

• Keep loose clothing, hair, fingers, and all parts of body away from openings and moving parts.

• Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes, or any

health endangering dusts.  Do not use to pick up flammable or combustible liquids such as gasoline or use
in areas where they may be present.

• Turn off all controls before unplugging.

• Use extra care when cleaning on stairs.

• Connect to a properly grounded outlet only.

• Liquid ejected at the spray nozzle could be dangerous as a result of its temperature, pressure, or chemical

content.

Summary of Contents for 56380568

Page 1: ...defoamer when foaming occurs to prevent vacuum motor damage 2 Keep machine from rain and snow extremes in temperatures and store in a heated location Use the machine indoors DO NOT let the machine fr...

Page 2: ...or dropped into water return it to a service center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine ove...

Page 3: ...machine to break up any mineral or chemical build up that may have formed The vacuum motor pump motor and the pump do not require any scheduled maintenance however the motors may require replacement...

Page 4: ...es are used to move the machine These handles allow you to tilt the machine back onto it s 12 wheels for easy maneuvering and or for moving on stairways DRAIN HOSE HANDLES VACUUM HOSE BARB FAN VACUUM...

Page 5: ...ing and will turn off when it reaches operating temperature During normal operation the MODE light will be on most of the time CARPET UPHOLSTERY SWITCH 5 This rocker switch activates a solenoid valve...

Page 6: ...s necessary 8 When finished with the job vacuum all unused solution into the recovery tank and dump the tank Clean the tanks and filters Clean the tool and hoses Store the machine in a heated location...

Page 7: ...gging cleaning tool or vacuum hose Drain gate is not completely closed or seals are damaged Vacuum dome is not seated or is damaged No power to motor Test the Electronic Float Test the switch Test the...

Page 8: ...s tirer sur le cordon utiliser le cordon comme une poign e fermer une porte sur le cordon ou enrouler le cordon autour de bords ou de coins ac r s Ne pas faire passer la machine sur le cordon loignez...

Page 9: ...e d un compos de rin age afin de dissoudre tout d p t de min raux ou de produits chimiques qui aurait pu s accumuler Le moteur d aspiration les moteurs de pompe et les pompes n ont pas besoin d un ent...

Page 10: ...gn es vous permettent d incliner la machine vers l arri re sur ses roues de 12 po 30 cm pour une manoeuvre facile ou un d placement dans les escaliers TUYAU DE VIDANGE POIGN ES RACCORD CANNEL DU TUYAU...

Page 11: ...ffe et s arr tera lorsqu il atteint la temp rature de fonctionnement Pendant une utilisation normale le t moin lumineux MODE sera presque toujours allum COMMUTATEUR TAPIS MEUBLES CAPITONN S 5 Ce commu...

Page 12: ...es r servoirs au besoin 8 Quand le travail est fini aspirer toute la solution inutilis e dans le r servoir de r cup ration et vidanger celui ci Nettoyer les r servoirs et les filtres Nettoyer l outil...

Page 13: ...exible d aspiration L opercule du drain n est pas compl tement ferm ou les joints d tanch it sont endommag s Le d me de l aspirateur n est pas bien fix ou endommag Pas de courant au moteur V rifiez le...

Page 14: ...31 45 36 37 40 38 46 55 57 56 58 62 60 64 66 67 68 53 52 73 70 72 51 50 49 1 5 3 3A 7 6 5A 6A 29 28 31 24 12 16 18 15 14 19 20 22 19 13 17 11 10 75 74 71 77 PUMP 9 26 34 63 54 44 42 41 43 65 15A 9A 1...

Page 15: ...3000 Bracket solenoid mounting 40 FP225 Vacuum Motor Control PCB 41 2014 Fan 120V 42 2015 Guard fan 43 2B1 Screw 6 32 X 2 1 4 44 1057B Power Cord 12 3 25 ft 45 1062 Receptacle AC power in 46 1476 Str...

Page 16: ...425 322 0133 800 257 7982 FAX 425 322 0136 11015 47th Ave W Mukilteo WA 98275 VISIT US AT http www usproducts com...

Reviews: