A-12 / ENGLISH
A-12
- FORM NO. 56041707 - Agitator
™
16 / 18 Clean & Restore
EN
AUTHORIZED PERSONNEL MAINTENANCE
SOLUTION PUMP REMOVAL
1 Drain the recovery and solution tanks and tip the machine over onto its side.
2
See Figure 8.
Remove the (2)
(A)
Screws and disconnect both bottom solution hoses
(B)
from the Solution Pump.
3 Tip the machine back upright, grab hold of the Operator’s Handle
(1)
and push down to tilt the entire recovery / solution tank assembly back.
BOTTOM VIEW OF MACHINE
4 Disconnect the top solution hose and the pump wiring connectors. The Pump
(C)
can now be lifted straight up and out of the base assembly.
NOTE:
Make note of the orientation of the pump mounts
(D)
for reassembly. Make note of the connection locations of the wiring for
reassembly.
5 Follow the above steps in reverse order to install the pump.