background image

2

IMPORTANT SAFETY INSTRUCTIONS

This machine is only suitable for commercial use, for example in hotels, schools, hospitals, factories, shops

and offices other than normal residential housekeeping purposes.

When using any electrical appliance, basic precautions should always be followed, including the following:

NOTE

: Read all instructions before using this machine.

  WARNING!

To reduce the risk of fire, electric shock, or injury:

INTRODUCTION

This manual will help you get the most from your COBRA-C2 Extractor

.

  Read these instructions thoroughly

before operating the machine.  This product is intended for commercial use only.

PARTS AND SERVICE

Call the distributor from whom you purchased your machine when you need parts or service.  Please
specify the Model and Serial Number when discussing your machine.

UNCRATING

When the machine is delivered, carefully inspect the shipping carton and the machine for damage.  If damage
is evident, save the shipping carton so that it can be inspected.  Contact the shipping company immediately
for instructions on how to file a freight damage claim.

SERIAL NUMBER PLATE

The Serial Number of your machine is shown on the plate that is mounted on the floor of the base
compartment.  This serial number and model are needed when ordering replacement parts for the machine.
Use the space below to note the Model and Serial Number of your machine for future reference.
MODEL :    

COB-C2-230CEN/A

            SERIAL NUMBER : _____________________________________

Be sure to go to www.usproducts.com to register your warranty on-line..

Do not leave the maching unattended when it is plugged in.  Unplug the unit from the outlet when not in use
and before servicing.

To avoid electric shock, do not expose to rain or snow.  Store, and use, indoors.

Do not allow to be used as a toy.  Close attention is necessary when used near children.

Use only as described in this manual.  Use only the manufacturer’s recommended attachments.

Do not use with damaged cord or plug.  If the machine is not working as it should, has been dropped,
damaged, left outdoors or dropped into water, return it to a service center.

Do not pull by the cord, use the cord as a handle, close a door on the cord, or pull the cord around sharp
edges or corners.  Do not run the machine over the cord.  Keep the cord away from heated surfaces.

Do not unplug by pulling on the cord.  To unplug, grasp the plug, not the cord.

Do not handle the plug, the cord or the machine with wet hands.

Do not put any object into openings.  Do not use with any opening blocked; keep free of dust, lint, hair, and
anything that may reduce air flow.

Keep loose clothing, hair, fingers, and all parts of body away from openings and moving parts.

Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes, or any
health endangering dusts.

Turn off all controls before unplugging.

Use extra care when cleaning on stairs.

Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may
be present.

Connect to a properly grounded outlet only.

Liquid ejected at the spray nozzle could be dangerous as a result of its temperature, pressure or chemical
content

.

Summary of Contents for COBRA-C2

Page 1: ...er regularly monthly or more often to prevent a build up of minerals or chemicals in the pump and heat systems Follow the flush with a clear water rinse to remove any particles and to rinse the acid f...

Page 2: ...sure to go to www usproducts com to register your warranty on line Do not leave the maching unattended when it is plugged in Unplug the unit from the outlet when not in use and before servicing To avo...

Page 3: ...float Shut OFF can also be accessed through this opening for maintenance Vacuum Inlet 5 This is where the vacuum hose attaches to the machine Latch 6 Open the latches to access the base compartment w...

Page 4: ...n the recovery tank any time foaming occurs 8 Monitor the water level in the solution tank Do not let the pump run dry 9 When the solution tank gets low turn off the pump fill the solution tank empty...

Page 5: ...ower to pump Test the switch Test the pump motor Partially clogged solution path hose heater tool Worn pressure switch in pump Adjust pressure sensor in pump head Debris plugging cleaning tool or vacu...

Page 6: ...7 9 12 10 15 17 18 18 3 20 25 21 22 40 41 42 43 44 45 46 47 48 49 58 50 51 52 62 69 14 16 66 COBRA C2 230 March 2007 19 56 11 12 13 14 30 61 60 59 58 69 57 55 54 53 29 64 56 1 6 5 3 2 4 8 22 23 30 30...

Page 7: ...p t 26 91 Elbow brass 1 4 n p t 27 2012 Hose 66 cm 28 108 Elbow Hose barb 29 925 Hose pump inlet 30 166 Hose Clamp 34 2017 Pump 100 psi 230V 40 270 Bolt 1 4 20 X 12 7 cm 41 137 Washer split lock 42 1...

Page 8: ...8 208 772 0573 800 257 7982 FAX 208 772 0577 Coeur d Alene Idaho VISIT US AT http www usproducts com NOTES COB C2 230CEN A...