SPECIFICATIONS:
Rotomolded Body:
Vacuum:
VAC Shutoff:
Pump:
Waterlift:
Heat:
Heater:
Wand:
Weight:
Dimensions:
Lifetime Warranty
3-stage
Ball
fl
oat
Demand pump, 100 psi
140”
212º F
2000 Watts
Stainless steel, single bend, twin tip
75 lbs.
25.5H x 18W x 28.75L (inches)
TROUBLE SHOOTING:
IF THIS
CHECK THIS
ALWAYS UNPLUG THE MACHINE BEFORE
DISCONNECTING OR CONNECTING ANY WIRES OR
COMPONENTS
.
NO SPRAY
PUMP DOES
NOT RUN
Solution tank is empty.
Clogged spray tip.
Pump not running.
Valve on wand not operating
No power to pump. Test the switch. Test the pump motor. Replace if necessary.
Debris plugging cleaning tool or vacuum hose.
Drain gate is not completely closed, or seals are damaged. Vacuum lid is not closed or gasket is damaged.
No power to motor. Test the switch. Test the vacuum motor.
Spraying too long. Try spraying for 12-15 seconds per cycle.
Heat exchanger needs to be
fl
ushed.
Wrong tool being used.
Too much water passing through, longer hose or larger diameter hose, than standard
Heat is not turned on. Either the green light must be on or the bypass switch must be turned on.
No power in the wall outlet - check to see if the breaker has tripped.
No power to the bypass switch - check wiring for ‘opens’.
No power out of bypass switch, follow troubleshooting steps to isolate the problem or call your distributor for
additional help
LOW SUCTION
NO SUCTION
LOW HEAT
NO HEAT
425-322-0133 / 800-257-7982 / FAX: 425-322-0136
11015 - 47th Ave. W. / Mukilteo, WA 98275
VISIT US AT: http://www.usproducts.com