background image

INSPECTION:
Carefully unpack and inspect your  COBRA PLUS-300 for shipping damage.  Each machine is tested and
inspected before shipping.  Any shipping damage incurred is the responsibility of the carrier.  You should notify
the carrier immediately if you notice damage to the box or to the machine or parts.

CLEANING SOLUTIONS:
We recommend liquid cleaning chemicals, such as our Magic Fabric Cleaner.  Powder chemicals may be used,
but unless mixed very thoroughly they could cause a build-up in the pump, lines, heat exchanger and/or
quick disconnects.  Any problem caused by a chemical build-up is not covered by warranty.  Use a neutral
cleaner with a pH between 6 and 9 to avoid premature wear of the pump, seals, and/or other components.
Damage caused by the use of strong chemicals is not covered by the warranty.

MAINTENANCE:
For optimum performance flush the machine with clear water at the end of each working day.  Once a
month, minimum, run a flushing compound  through the machine to break up any mineral or chemical build-
up that may have formed.  U.S. Products “X-1500” is recommended.  The vacuum motor, pump motor, and
the pump do not require any scheduled maintenance; however, the motors may require replacement brushes
after 1000 - 1500 hours, and the pump and bypass valve may require rebuild kits after 1000 - 1500 hours,
typically (refer to machine part list for numbers)  Clean the body with an all purpose detergent, and protect it
with an automobile interior polish.  Lubricate the wheels, castors, and quick disconnects with an all purpose
silicone spray.

Recovery

Tank Lid

Switch

Plate

Vacuum Hose

Connection

Solution Hose

Connection

Vacuum Hose

and Solution

Hose on Reel

Latch

 Wheel

Pressure Gauge

Castor

Solution Tank Lid

Dump Hose

Summary of Contents for COBRA PLUS-300

Page 1: ...ming occurs to prevent vacuum motor damage 2 Keep machine from rain and snow extremes in temperatures and store in a heated location Use the machine indoors Do not use outdoors 3 Do not let the pump r...

Page 2: ...ed into water return it to a service center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the cor...

Page 3: ...ong chemicals is not covered by the warranty MAINTENANCE For optimum performance flush the machine with clear water at the end of each working day Once a month minimum run a flushing compound through...

Page 4: ...ight up If the locator light does not come on try different outlets with one of the cords until it does If you are certain the cords are on separate circuits turn the Bypass switch on CAUTION using th...

Page 5: ...emove any unused solution from the solution tank and run a few gallons of clean water through the system Drain the recovery tank by placing the dump hose over a drain or a bucket and removing the cap...

Page 6: ......

Page 7: ...45 Quick connect male 1 4 p t 38 1057B Power Cord 12 3 25 yellow 39 1062 Recepticle power cord 40 1128005 Label CP 300 41 910 Axle rod 18 1 4 42 27A Axle cap 43 2084 Wheel 10 44 923B Dual cord sensor...

Page 8: ...SPECIFICATIONS Rotomolded Body Vacuum VAC Shutoff Pump Waterlift Heat Heater Wand Weight Dimensions Lifetime Warranty 7 2 3 stage soft start vac Electronic Positive displacement fully adjustable 0 30...