background image

9

KING COBRA-500-ADAF

Part List

FP436 

Chain, for lid

901B 

Lid, for solution tank

3 HKCR-1  Holding 

Tank

4 1088 

Glide, 

Tefl on, for reel

5 913 

Vacuum 

motor

6 959 

Gasket, 

vacuum

8 1136 

Hose, 

vacuum

9 926 

Manifold, 

gasket

10 

907 

Hose barb, vacuum inlet

11 

2086A 

Lid & Ring, vacuum tank

12 

1074 

Gasket, vacuum lid

13 2026 

Float, 

electronic

14 

926 

Filter, vacuum inlet

15 

1060C 

Cap, drain hose

16 1060B 

Hose, 

drain

17 1518 

Clamp, 

hose

18 CWKC-BLK Cord 

Wrap

19 

1130 

Strap, hook & loop

20 

1088 

Glide, for reel

21 

925 

Hose, pump inlet, 1/2” X 24”

22 

FP410 

Pump complete, no motor

23 

948B 

Motor, pump drive

24 

945D 

Valve, pressure regulator

25 

944 

Hose, pump to gauge

26 

946 

Hose, pump bypass, 3/8” X 24”

27 

FP411A 

Hose, pump to heater, w/QDs

28 928 

Louver, 

3”

29 

FP361 

Control board, pump motor speed

30 2088 

Pre-fi lter, vac inlet

32 

FP225 

Control board, vacuum soft start

34 

1062 

Receptacle, power cord

35 

1057B 

Power cord, 25 ft

37 

45 

Quick disconnect, solution output

38 

1146 

Pipe, 1.4 pipe X 6.85”

39 

1144A 

Tubing, 5/8” X 5”

40 

HKCR-1 

Tank, solution holding

42 78B 

Light, 

Red

44 248 

Knob, 

red

45 

FP347 

Potentiometer, with wires, for heat

47 

FP346 

Switch, Heat Bypass

48 FP345 

Switch, 

Vacuum

49  

249 

Knob, Pump pressure control

50 

FP399 

Potentiometer, with cable, pump

52 78 

Light, 

green

54 

951B 

Gauge, pump pressure

ITEM PART No 

DESCRIPTION

120V

6-4-2009

55 

943B 

Plate, switch holding

56 

2067 

Pump, auto pump out

58 

1081 

Elbow/Hose barb, 90°

59 

239 

Coupling, Hose adaptor

60 

237 

Cap, for hose fi tting

61 1128 

Label

62 

910-21.00 

Axle rod, 21”

63 2084 

Wheel, 

10”

65 27A 

Axle 

cap

66 

932B 

Circuit board, dual circuit detect

67 

FP336 

PCB mounting track, 4”

69 

FP194E 

Heat repair kit

70 

918 

Heat sink plate

72 198 

Clamp, 

hose

73 

FP348 

Heat exchanger, complete

75 

1134 

Hose, Heater to outlet, 29”

77 

445 

Plate, heater mounting

79 

901B 

Lid, for solution holding tank

80 805 

Chain

81 BKCR-BLK  Base 

compartment

82 1043A 

Gasket, 

93.5”

83 1014 

Fan, 

cooling

84 2015 

Guard, 

fan

85 

908A 

Latch and strike

89 HKCR-1 

Holding 

tank

90 

2069 

Filter, dump pump inlet

91 1320A 

Bracket

92 1310A 

Valve, 

auto-fi ll shut-off

94 

207A 

Filter, solution pump inlet

 

 

ITEM PART No 

DESCRIPTION

Miscellaneous parts and Assemblies

FP409 

Pump and motor, complete w/unloader

950CP 

Pump rebuild kit, valves and O-Rings

250 

Pump rebuild kit, piston and seals

SYP1 Priming 

hose

FP350C  Pressure line and vacuum hose, complete

FP469 

Swivel and hose assembly, 16-1/2”

948C 

Brush, carbon, for pump motor (order 2)

Summary of Contents for KING COBRA 500-ADAF

Page 1: ...R USE OF THE MACHINE WILL VOID THE WARRANTY 1 Always use a defoamer when foaming occurs to prevent vacuum motor damage 2 Connect the machine to a properly grounded outlet only 3 Keep machine from rain...

Page 2: ...C 130 F to the solution tank Do not use with damaged cord or plug If the machine is not working as it should has been dropped damaged left outdoors or dropped into water return it to a service center...

Page 3: ...tween 5 and 10 to avoid premature wear of the pump seals and or other components It is a good idea to test an inconspicuous area of the floor MAINTENANCE For optimum performance flush the machine with...

Page 4: ...s regarding dilution and mixing Do not use harsh chemicals they may damage seals in pumps and valves If you choose to use the auto fill feature connect the fill hose to the auto fill hose connector lo...

Page 5: ...bucket or drain Unplug the power cords 15 Disconnect the hoses from the cleaning tool Reel up the hoses 16 Clean the machine and the tool Never store your machine outside and always keep it from extr...

Page 6: ...he tank is free of obstruction and can move freely Turn on the water supply The auto fill does not require high pressure just turn the water on but not on full pressure The auto fill float will automa...

Page 7: ...end of the hose into a drain Turn the dump pump switch ON switch is located on the back of the machine next to the pump NOTE the dump pump is self priming You should see water start to flow within 30...

Page 8: ...009 120V AC 50 52 54 55 56 58 59 60 62 63 65 66 67 69 70 72 73 75 77 79 80 81 82 83 84 85 28 89 20 90 91 92 94 86 61 1 2 3 4 5 6 8 9 10 11 13 18 20 21 22 23 24 25 27 28 26 29 30 32 34 35 37 38 39 40 4...

Page 9: ...47 FP346 Switch Heat Bypass 48 FP345 Switch Vacuum 49 249 Knob Pump pressure control 50 FP399 Potentiometer with cable pump 52 78 Light green 54 951B Gauge pump pressure ITEM PART No DESCRIPTION 120V...

Page 10: ...Longer hose or larger diameter hose than standard Heat is not turned on No power in the wall outlet check to see if the breaker has tripped No power to the heat switch check wiring for opens No power...

Reviews: