U.S. Solid Ba+ery Spot Welder USS-BSW00007 Manual, Version 4.1, 2022.8.16
New Func+ons - Super Power ‘AL-NI’ Mode & Time-delay Welding
‘AL-NI’
Press the ‘LFP/NCR’ bu6on to turn on the ‘AL-NI’ super power mode, the
capacitor voltage will be charged up to 6V in this mode, 0.2mm pure nickel
can be directly welded to the aluminum terminals of LiFePO4, LiPo, etc.
(Tips: 75A separated-style welding pen is especially designed for LFP ba+ery
welding)
Time-delay
Press the ‘DISCH DELAY’ bu6on to switch the ?me-delay senng(set the ‘AL-
NI’ super power mode and ‘AT’ welding mode firstly)
When ‘LO MI SS’ Signal is flashing, the pulse delay ?me is 100ms;
When ‘SS’ signal is normally on, the pulse delay ?me is 200ms;
When ‘MI’ signal is normally on, the pulse delay ?me is 300ms;
When ‘LO’ signal is normally on, the pulse ?me is 400ms;
Press the ‘DISCH DELAY’ bu6on for 2 seconds when ‘LO MI SS’ signal is
flashing. The ‘LO MI SS’ signal will be normally on and the pulse delay ?me
is 500ms, you can press the ‘DISCH DELAY’ bu6on again for 2 seconds to
cancel this senng.
Tips:
1. Time-delay funcSon only works under ‘AL-NI’ super-power mode & ’AT’
welding mode, other modes have a preset fixed Sme-delay se[ng.
2. Dual pulses are released when Sme-delay se[ng is 500ms(only).
5