background image

 1.  To prevent electrical shock, disconnect transformer from electrical supply before installation or service.
      

NOTE: 

DO NOT pull the underwater cable. If wire is pulled, it may break the liquid tight seal  

                    and void the warranty.
      

NOTE: 

DO NOT loosen or remove the liquid tight connector. This will damage the factory set  

                    seal and result in possible leakage.
      

NOTE: 

The end of the underwater cable must be potted to prevent moisture from entering the 

                    cable and consequently entering the luminaire. Connection or splicing of cable must be
                    made away from the water and at least 4 feet from the water edge. This luminaire comes 
                    equipped with 15 feet of waterproof cable to facilitate installation away from the water. 
      

NOTE: 

Each luminaire is factory tested prior to shipment. Traces of water may be visible

                    as a direct result of factory underwater testing.
 2.  Strip the two (2) leads from the luminaire. Using the two (2) silicone filled connectors (provided),
      connect the leads from the luminaire to the main supply cable leads.
 3.  Supply power to luminaire and check for proper operation.

                            INSTRUCTIONS FOR REFLECTOR INSTALLATION

      

NOTE:

 Your Vista model 4217 is provided with a  spread reflector to disperse light out the sides of the

                    luminaire giving a wash effect if desired. Follow instructions below for installation.
 1.  To prevent electrical shock, disconnect transformer from electrical supply before installation.
 2.  Loosen the four (4) luminaire lens screws and remove lens and O-ring.
 3.  Insert reflector into lens, slipping the square holes in reflector onto the round pegs in lens as illustrated.
 4.  Clean O-Ring and channel and re-install O-Ring.
 5.  Re-install lens and tighten the four screws evenly.

       IMPORTANT SAFETY INSTRUCTIONS - LIGHTED LAMP IS HOT!!
  WARNING: TO REDUCE THE RISK OF FIRE, OR INJURY TO PERSONS: 

1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamps get hot quickly! Contact only switch/plug when turning on.
3. Do not touch hot lens, guard or enclosure.
4. Keep lamp away from material that may burn.
5. Do not touch the lamp at any time. Use a soft cloth. Oil from 
    the skin may damage lamp.
6. Do not operate luminaire fitting with a missing or damaged cover. 

      

CAUTION: LUMINAIRE IS RATED AT 12 VOLT AC. DO NOT CONNECT 

                           

LUMINAIRE TO ANY OTHER VOLTAGE.

    LAMP INSTALLATION/REPLACEMENT:
    CAUTION: Do not exceed maximum wattage marked on luminaire label.

1. To prevent electrical shock, disconnect transformer from electrical supply before service.
2. Loosen the four (4) luminaire lens screws and remove lens and O-Ring.
3. Replace lamp with correct wattage and type marked on fixture label.
    

NOTE: 

DO NOT touch Halogen lamp with bare hands. Always use soft cloth or the

                  plastic wrapping (if available) from the lamp to handle the lamp.
4. Clean O-Ring and channel and re-install O-Ring.
5. Re-install lens and tighten the four (4) screws evenly.

VISTA PROFESSIONAL OUTDOOR LIGHTING                              Division of U.S.T.E. Inc.                          Website: www.vistapro.com        
1625 Surveyor Avenue, Simi Valley, CA 93063                (805) 527-0987          FAX: (805) 527-6830           (800) 766-8478

Reviews: