background image

Solar Charge Controller 6830-122-C10/15/20 

2013-06-25                2                    Version 6 

2 General Information 

2.1 Product Overview   

Thank you for selecting U-Tron LS series solar light controller that adopts 

the most advanced digital technique and operates fully automatically. The 

Pulse Width Modulation (PWM) battery charging can greatly increase the 

lifetime of battery. It has various unique functions and quite easy to use, such 

as: 

12/24V automatic recognition 

High efficient Series PWM charging, increase the battery lifetime and 

improve the solar system performance. 

Use MOSFET as electronic switch, without any mechanical switch 

Widely used, automatically recognize day/night.

 

Digital LED menu, only one key solve all setting simply 

Intelligent timer function with 1-15 hours option   

 Unique dual timer function, enhance the flexibility of street light system. 

 Gel, Sealed and Flooded battery type option. 

Adopt  temperature  compensation,  correct  the  charging  and  discharging 

parameters automatically and improve the battery lifetime.

 

Electronic  protection:  Overheating,  over  charging,  over  discharging, 

overload,

 

and short circuit.                                             

Reverse protection: any combination of solar module and battery. 

 

The controller is for off-grid solar system, especially in solar light system, 

and protects the battery from being over charged by the solar module and 

over discharged by the loads. The charging process has been optimized for 

long battery life and improved system performance. The comprehensive 

self-diagnostics and electronic protection functions can prevent damage from 

installation mistakes or system faults. 

 

Though the controller is easy to operate and use, please take your time to 

read this manual and become familiar with it. This will help you make full 

use of all the functions and improve your solar PV system. 

Solar Charge Controller 6830-122-C10/15/20 

2013-06-25                3                    Version 6 

2.2 Product Features 

 

Figure 2-1    Land Star characteristics

 

1 –Temperature Sensor   

Measure ambient temperature and make temperature compensation for 

charging and discharging. 

 

– 

Charging status LED indicator 

An LED indicator that shows charging status and also indicates when battery 

voltage is higher than over voltage disconnect voltage. 

3 – Battery status LED indicator   

An LED indicator that shows battery status   

4 – Battery type setting indicator 

The indicator will be on when select battery type. 

5 – Timer 2 setting indicator   

The indicator will be on when set timer 2. 

6 – Timer 1 setting indicator   

The indicator will be on when set timer 1. 

7 –LED digital display 

Display the load work mode and status   

8 –Setting button 

Solar Charge Controller 6830-122-C10/15/20 

2013-06-25                4                    Version 6 

Set load work mode and select battery type (in manual mode used for load 

ON/OFF). 

9 –Solar Module Terminals   

Connect solar modules. 

10 –Battery Terminals 

Connect batteries.   

11 –Load Terminals 

Connect loads.   

3 Installation Instructions   

3.1 General Installation Notes   

Read through the entire installation section first before beginning installation. 

Be very careful when working with batteries. Wear eye protection. Have 

fresh water available to wash and clean any contact with battery acid. 

Uses insulated tools and avoid placing metal objects near the batteries. 

Explosive battery gasses may be present during charging. Be certain there 

is sufficient ventilation to release the gasses. 

Avoid direct sunlight and do not install in locations where water can enter 

the controller. 

Loose power connections and/or corroded wires may result in resistive 

connections that melt wire insulation, burn surrounding materials, or even 

cause fire. Ensure tight connections and use cable clamps to secure cables 

and prevent them from swaying in mobile applications. 

Use with Gel, Sealed or Flooded batteries only. 

Battery connection may be wired to one battery or a bank of batteries. The 

following instructions refer to a singular battery, but it is implied that the 

battery connection can be made to either one battery or a group of 

batteries in a battery bank. 

 Select the system cables according to 3A/mm

2

 current density   

Solar Charge Controller 6830-122-C10/15/20 

2013-06-25                1                    Version 6 

3.2 Mounting

 

NOTE: When mounting the controller, ensure free air 

through the controller heat sink fins. There should be at 

least 6 inches (150 mm) of clearance above and below the 

controller to allow for cooling. If mounted in an   

                          enclosure, ventilation is highly recommended. 

WARNING: Risk of explosion! Never install the 

controller in a sealed enclose with flooded batteries! Do 

not install in a confined area where battery gassed can   

                         

accumulate.

 

 

Step 1: Choose Mounting Location 

Locate the controller on a vertical surface protected from direct sun, high 

temperature, and water. And make sure good ventilation. 

Step 2: Check for clearance 

Place the controller in the location where it will be mounted. Verify that 

there is sufficient room to run wires and that there is sufficient room above 

and below the controller for air flow. 

 

Figure 3-1    Mounting and cooling 

Warm air 

Cool air 

150mm(5.9inches) 

150mm(5.9inches) 

Summary of Contents for 6830-122-C10

Page 1: ...tions Troubleshooting and Maintenance 18 5 1 Protection 18 5 2 Troubleshooting 19 5 3 Maintenance 21 6 Warranty 22 7 Technical Specifications 23 Solar Charge Controller 6830 122 C10 15 20 2013 06 25 1...

Page 2: ...when set timer 2 6 Timer 1 setting indicator The indicator will be on when set timer 1 7 LED digital display Display the load work mode and status 8 Setting button Solar Charge Controller 6830 122 C1...

Page 3: ...istance between the fuse holder and the positive terminal of battery is 150mm Do not insert a fuse at this time Confirm the connection correct and turn on the power Battery Fuse Battery 150mm 5 9inche...

Page 4: ...t point When the battery is fully recharged there will be no more chemical reactions and all the charge current transmits into heat and gas at this time Then the controller reduces the voltage to the...

Page 5: ...tal tube showing H with slowly flashing simultaneously Please refer to section 5 for trouble shooting Overheating protection indicator Table 4 4 Color LED digital tube System status Red H with slowly...

Page 6: ...tes delay since sunset 9 Load will be on for 10 hours after ten minutes delay since sunset 10 Load will be on for 11 hours after ten minutes delay since sunset 11 Load will be on for 12 hours after te...

Page 7: ...return to green automatically when fully charged Solar Charge Controller 6830 122 C10 15 20 2013 06 25 11 Version 6 Digital tube displays L with red slowly flashing Over load or short circuit Overload...

Page 8: ...st Reconnect Charging Voltage 13 2V x2 24V 13 2V x2 24V 13 2V x2 24V Low Voltage Reconnect Voltage 12 6V x2 24V 12 6V x2 24V 12 6V x2 24V Under voltage warning reconnect voltage 12 2V x2 24V 12 2V x2...