7 |
P a g e
the lock is reset to the original manufacturer’s defaults. Once a total of 10
unused
service
keypad codes are programmed in, the E5 will not allow any additional service keypad
code entries until at least one of the existing service keypad codes are removed by using
them. Service keypad codes do not have index numbers. Any number of service keypad
codes up to 10 can be programmed into the
non-software
E5 at one time or just one at a
time.
Software version E4 / E5:
A total of 10 one-time use keypad service codes are permitted and are typically
used to allow maintenance or vendors a single access. When a service keypad code is
used and the E4 / E5 is currently locked it will unlock. (If it is already unlocked, the E4 /
E5 will relock.) Once programmed into the E4 / E5, these service keypad codes remain
unless used or the lock is reset to the original manufacturer’s defaults. Once a total of 10
unused
service keypad codes are programmed in, the E4 / E5 will not allow any
additional new service keypad code entries until at least one of the existing service
keypad codes are removed by using them. Service keypad user codes do not have index
numbers. Service keypad codes can only be programmed into the
software version
E4 /
E5 one at a time for a total of 10.
Index Number
Non-software E5 lock:
Users are automatically assigned an ‘Index number’ in the order that they are
added to the E5, beginning at 001 and incrementing by one at every new user. (That is,
001,002,003,004, etc
.). This index number is required if you later want to delete a
user from the lock
. The maximum number of users is 299. You should keep track of
what this index number is for each user as you enter them. There is no way to obtain the
index number from the lock if you should later need it, so it is best to keep track of it
while you enter the user codes. The index number is always expresses as 3 digits.
Software version E5:
When the software version of the E5 is
manually
programmed from the keypad
on the lock, users are automatically assigned an ‘Index number’ in the order that they are
added to the E5, beginning at 001 and incrementing by one at every new user. (That is,
001,002,003,004, etc
.). Either the index number OR the user access code is required
if you later want to delete a user from the lock
. The maximum number of users is 299.
A handy index / user code chart can be found on page 18 of this manual.
You should keep track of what this index number is for each user as you enter
them. There is no way to obtain the index number from the lock if you should later need
it, so it is best to keep track of it while you enter the user codes. The index number is
always expresses as 3 digits. Index numbers do
not
apply to the software version E4 / E5
when programmed with a personal computer
, only when manually programmed from
the keypad on the E4 / E5.