13
revised 09/09
Smog-Hog
SG Series Model
collection components should be removed and
replaced with great care to preserve gasket integrity.
Should damaged gasket require replacement, call UAS
customer Service for the proper gasket material.
GASKET LENGTHS
9.6 POWER PACK ENCLOSURE PUSH ROD
ADjUSTMENT
Tools required:
• 6” adjustable or 5/16” open-end Wrench.
refer to figure 11.
1. close module door (10) with unicells installed.
2. open power pack enclosure lid cover (3).
3. Loosen 5/16” hex jam nut (9), then back off push
rod extension (1) to end of threads.
4. close power pack enclosure lid cover, listening
for point where limit switch (4) is engaged.
5. Adjust rod extension (1) inward until limit switch
(4) engages approximately one inch before the
power pack enclosure lid cover closes (3).
6. Tightened hex jam nut.
7. close power pack enclosure pack lid cover
(3) and latch.
uaS
nuMBer of
LenGtH
MoDeL
DoorS
Per Door (ft.)
SG-2
1
6
SG-4S
1
10.5
SG-4t
2
6
SG-6
1
16
TO CHANGE GASKET
refer to figure 18
1. Remove existing gasket, making sure to scrape off
any residual silicone sealant.
2. trim one edge of gasket neatly and evenly.
3. the door gasket internally has three lips to one side
of the gasket and one lip to the other side. the door
gasket should be installed with the three lips towards
the interior of the cabinet.
4. the door gasket should be formed to the complete
cabinet flange before applying silicone sealant.
Place the trim edge at the top center of the cabinet
lip edge and press gasket in place, ending at the
same location. Do not trim excess door gasket.
5. remove door gasket and apply silicone sealant to
the inside of gasket or on the inside edge of the
cabinet flange. Place the trim edge at the top center
of the cabinet lip edge and press gasket in place,
ending at the same location. Trim excess gasket
and remove silicone sealant. Make sure the gasket
is firmly bottomed on the flange by tapping with a
rubber mallet or the gasket may not seal against the
door properly.
6. check that the distance from the inner face of the
access door to the latch tongue measures 7/8”. Slight
adjustments may be necessary due to sheet metal
variations.
Figure 18
Door Gasket Installation