3.4 MECHANICAL INSTALLATION
CRUSH HAZARD
use adequate safety measures when lifting and
assembling any heavy components. consult your
plant safety personnel for recommendations.
connect lifting slings and spreader bars to lifting lugs
with clevis pins. use spreader bars to distribute the
load evenly. Location must be clear of all obstructions,
such as utility lines or roof overhangs.
unit should always be secured to the machine or
stand
in most installations the SHM unit is to be mounted on
to a machine, to illustrate the bolt pattern and hardware
required for proper mounting to the customer equipment.
All units utilize an 8˝ inlet and optional collar flange that
come mounted to the unit. they can be connected to your
machine however desired based on application needs. Be
sure to use a polyurethane sealant or gasket to prevent
leaks. it is recommended to use ducting that is liquid tight
to prevent leaks.
all other transitions, ducting or plenums required for
unit set-up and operation are not included with the
equipment.
Secure the unit at all four corners using the standard unit
feet. See figure 1 for reference.
Ceiling mounted
units are suspended by means of 1⁄2˝
threaded rods (item #1 in figure 3a) which run through
weld nuts (item #2 in figure 3a) in the top corners of the
units. refer to figure 2 for weld nut locations on SHM
models. Additional support should be used for auxiliary
equipment or ducting.
CAUTION
the SMoGHoG should not be used for support of
personnel or material. check with local building code/
structural engineer to ensure proper installation to roof
truss or any other mounting method.
the customer or installer is responsible for supplying
any required hanging hardware, and takes full
responsibility for confirming adequate structural
support and safety of hanging installation.
Metal Truss Supported Ceilings.
figure 3a shows an
example of a SHM unit suspended from a metal truss
supported ceiling. customer should take care to determine
that the truss will be sufficient to support the weight. as
shown, angle iron braces are secured between two steel
trusses. rod length should be kept to a minimum and cut
to length as necessary.
FIGURE 3A
Ceiling Mounted Unit
Be sure rods are threaded adequately into the weld nuts,
about 1˝ (25.4 mm) of rod extending inside the cabinet is
acceptable.
tighten lock nuts (item #3 in figure 3a) in place to be sure
unit does not vibrate loose or fall over time.
!
D A N G E R
CAUTION
Summary of Contents for SMOGHOG SHM-05C
Page 1: ...Model SHM 05C Shown SMOGHOG Media Mist Collector l Models SHM 05C SHM 08C OWNER S MANUAL ...
Page 11: ...REV 17F SMOGHOG SHM Series Models 7 FIGURE 3B Typical Machine Mount 61 10144 ...
Page 14: ...REV 17F SMOGHOG SHM Series Models 10 61 10129 Figure 4 Remote Panel Touchscreen Connection ...
Page 16: ...REV 17F SMOGHOG SHM Series Models 12 61 10133 Figure 5 SHM Filter Removal Installation ...
Page 26: ...REV 17F SMOGHOG SHM Series Models 22 61 10134 Figure 22 ...
Page 27: ...REV 17F SMOGHOG SHM Series Models 23 A1 BASIC UNIT 04 001990 ...
Page 28: ...REV 17F SMOGHOG SHM Series Models 24 A2 REMOTE PANEL TOUCH CONTROLS 04 001802 ...
Page 29: ...REV 17F SMOGHOG SHM Series Models 25 A3 ADVANCED UNIT WITH REMOTE CONTROLS 04 002235 ...
Page 30: ...REV 17F SMOGHOG SHM Series Models 26 A4 575 480 TRANSFORMER 04 001717 ...