reV: 17f
SMoGHoG
®
SHM Series Models
15
4.3.3 BASIC SCREENS
Filter Screen:
Figure 8
the filter screen can be displayed by the operator by
selecting the filter status icon on the Home screen shown
in figure 8. the filter screen will then be displayed with
all available filters. this screen will display the differential
pressure across the filter during operation.
Blower Screen:
Figure 9
the standard blower screen will display the status
of the blower. if your equipment is equipped with the auto-
flow option and it is activated, the Blower screen will look
different than that shown in figure 9. refer to section
4.3.4 for additional details. the only time the blower
will shut down is when the blower has an internal fault.
Such faults as: Low line voltage, phase to phase issues,
ground issues, temperature issues, or for a catastrophic
failure. if the blower shuts down, refer to Section 6 for
troubleshooting.
on the blower screen you are able to adjust the speed
of the blower using one of two different methods. the
first adjustment can be done using the up/down arrows.
this adjustment will achieve a change of +/- 1%. this will
increase or decrease the airflow adjustment by 1% for
each touch of the up or down arrows.
the second method of airflow adjustment is to touch the
box that shows the percentage of the airflow. A number
pad will be shown in a pop up screen. you can enter any
number between 20 and 100. this will correspond to the
percentage of blower capability. the blower is capable
of 2,600 rPM at 100%, 1,950 rPM for 75%, 1,300 rPM
for 50%, and 520 rPM for 20%. these numbers are
approximate and may display slightly differently on any
given unit. there is a minimum set point for speed which
is 20% for the purposes of the blower design.
Information Screen:
Figure 10
the information screen will provide a phone number
for customer service. there is also a web address for
our website that can be used to locate your nearest
representative. Language selection can be made by
pressing the about button shown in figure 10.
then press the button that says english to toggle through
the selectable languages until you reach the desired one.
Languages with unique characters will require a different
program be loaded into the PLc/touchscreen. this
should only be done before the unit is shipped, by a
technician during install, or with guidance from a uaS
representative.
4.3.4 AUTO-FLOW SCREEN
Figure 11
When auto-flow is installed and activated the blower
screen will look like figure 11. refer to section 4.3.6 to
activate the auto-flow option and to make adjustments to
your flow target. the auto-flow blower screen will show
the target flow, the actual flow, the blower speed, and
the % of total speed available. the screen will also show
blower status. if there is a warning or fault, refer to the
troubleshooting section for guidance.
Airflow Adjustment
100%
About
English
Program:
Language:
Firmware Revision:
Major Build:
Minor Build:
Version 2.6.2
Version 1.3
4
3
6
Auto-Flow Seng
800 CFM
Summary of Contents for SMOGHOG SHM-05C
Page 1: ...Model SHM 05C Shown SMOGHOG Media Mist Collector l Models SHM 05C SHM 08C OWNER S MANUAL ...
Page 11: ...REV 17F SMOGHOG SHM Series Models 7 FIGURE 3B Typical Machine Mount 61 10144 ...
Page 14: ...REV 17F SMOGHOG SHM Series Models 10 61 10129 Figure 4 Remote Panel Touchscreen Connection ...
Page 16: ...REV 17F SMOGHOG SHM Series Models 12 61 10133 Figure 5 SHM Filter Removal Installation ...
Page 26: ...REV 17F SMOGHOG SHM Series Models 22 61 10134 Figure 22 ...
Page 27: ...REV 17F SMOGHOG SHM Series Models 23 A1 BASIC UNIT 04 001990 ...
Page 28: ...REV 17F SMOGHOG SHM Series Models 24 A2 REMOTE PANEL TOUCH CONTROLS 04 001802 ...
Page 29: ...REV 17F SMOGHOG SHM Series Models 25 A3 ADVANCED UNIT WITH REMOTE CONTROLS 04 002235 ...
Page 30: ...REV 17F SMOGHOG SHM Series Models 26 A4 575 480 TRANSFORMER 04 001717 ...