background image

reV: 17f

SMoGHoG

®

SHM Series Models 

1

1.  IMPORTANT NOTICE

this  manual  contains  important  safety  information  and 

precautionary measures. it is impossible to list all potential 

hazards associated with every collection system in each 

application.  Proper  use  of  the  equipment  should  be 

discussed with 

United Air Specialists, Inc. (UAS) or your 

local  UAS  representative

.  operating  personnel  should 

be  aware  of,  and  adhere  to,  the  most  stringent  safety 

procedures.

2.  INTRODUCTION

thank you for selecting uaS oil mist collection equipment 

to  assist  you  in  your  commitment  to  a  clean  and  safe 

environment.  We  trust  that  in  purchasing  our  product,  

you  have  recognized  our  commitment  to  offering  air 

cleaning  equipment  which  is  engineered  to  each  oil 

mist  collection  need  and  manufactured  to  the  highest 

standards. if at any time you have a question about oil mist 

collection,  please  do  not  hesitate  to  call  your  local  uaS 

representative. 
the  purpose  of  this  manual  is  to  provide  the  proper 

operating  and  maintenance  guidelines  for  the  SHM 

system  supplied  by  uaS.  as  you  review  this  manual,  

refer  to  figure  1  for  assistance  in  identifying  oil  mist 

collector parts.
the SHM oil mist collector has been designed to provide 

you  with  exceptional  oil  mist  collection  capabilities  and 

reliable,  long‐term  field  operation.  We  suggest  that  you 

thoroughly  review  this  manual  prior  to  installation  and 

startup of your system.
if  your  SHM  has  optional  equipment  included  as  part  of 

your order, specific operations and maintenance manuals 

for these accessory systems will be included. if applicable, 

site  specific  installation  and  other  drawings  will  also  be 

included.
if  you  require  assistance  in  the  installation,  startup, 

operation,  maintenance  or  troubleshooting  of  your 

air  cleaning  equipment,  contact  your  local  uaS  sales 

representative.

2.1 SMOGHOG NOMENCLATURE

SMoGHoG oil mist air cleaners are available in a variety 

of  configurations  and  sizes.  the  model  string  for  each 

given unit represents the base configuration. the model 

number completely identifies the design and can be found 

on the unit nameplate. SHM models are defined according 

to descriptions listed below (see bold):

 SHM-0XC-A

 

   

                 advanced unit

 

       cartridge Style filter

 

              nominal rated airflow

5

 - 500 cfM, 4 filter cartridges 

8

 - 800 cfM, 6 filter cartridges

Models  SHM-05C, SHM-08C, SHM-08C-A ADVANCED

the SMoGHoG is a machine mounted, self contained, oil 

mist filtering unit with left, right or rear inlet, combination 

sump and filter cabinet, primary filter, blower cabinet, and 

controls.  optional  after  filters  are  available  for  second 

stage filtration.

2.2 EQUIPMENT DESCRIPTION

this  section  will  briefly  describe  each  component  in  the 

SHM and its role in the system’s operation.

Filter Cabinet

each  unit  has  a  filter  access  door  that  provides  access 

to  the  primary  filters  for  service  and  replacement.  the 

PeacH  coalescing  filter  cartridges  are  slid  into  place 

between two tubesheets, concentric with the holes on both 

top and bottom.

Filter Elements

Primary coalescer cartridges featuring PeacH

®

 Saturated 

depth coalescing technology

Sump

units will include a sump where all contaminant will collect 

as it drips from the filter cartridges. A 1-1/2˝ FNPT coupling 

is  welded  into  the  back  side  of  the  sump  allowing  the 

collected contaminant to be reclaimed or drained. 

Blower Cabinet

units  will  have  a  blower  cabinet  where  the  motorized 

impeller style blower is housed, as well as the electrical 

controls.

Summary of Contents for SMOGHOG SHM-05C

Page 1: ...Model SHM 05C Shown SMOGHOG Media Mist Collector l Models SHM 05C SHM 08C OWNER S MANUAL ...

Page 2: ... following information available when contacting UAS UAS ORDER _________________________________________________________________ UNIT MODEL ________________________________________________________________ UNIT SERIAL _________________________________________________________________ SYSTEM ACCESSORIES ______________________________________________________________________________ ___________________...

Page 3: ...act 11 3 6 Filter Installation 11 3 6 1 Installation Procedure for After Filters 11 3 7 Drains 13 4 UNIT OPERATION 13 4 1 Start up 13 4 2 System Operation 13 4 2 1 Advanced Unit Operation 13 4 2 1 1 Airflow Adjustment Using Manual Speed Control 13 4 2 1 2 Airflow Adjustment Using Auto Flow Control 13 4 3 Touchscreen Operation 14 4 3 1 Start Up And Home Screen 14 4 3 2 Standard Format 14 4 3 3 Basi...

Page 4: ...terials and vapors such as gasoline away from the unit The unit should be inspected frequently and contaminants removed to prevent excessive accumulation which may result in flash over or fire damage Operate only in a safe and serviceable condition Operating temperature to the air stream should not exceed 120 F 49 C DANGER WARNING WARNING CAUTION C A U T I O N This is the safety alert symbol This ...

Page 5: ...gs will also be included If you require assistance in the installation startup operation maintenance or troubleshooting of your air cleaning equipment contact your local UAS sales representative 2 1 SMOGHOG NOMENCLATURE SMOGHOG oil mist air cleaners are available in a variety of configurations and sizes The model string for each given unit represents the base configuration The model number complet...

Page 6: ...REV 17F SMOGHOG SHM Series Models 2 FIGURE 1B SHM 05C Basic Equipment Description 61 10128 61 10128 FIGURE 1A SHM 05C Basic Equipment Description ...

Page 7: ...REV 17F SMOGHOG SHM Series Models 3 FIGURE 1D SHM 08C Advanced Equipment Description FIGURE 1C SHM 08C Advanced Equipment Description 61 10129 61 10129 ...

Page 8: ...s during operation The collected contaminate is drained off of the coalescing filters into the sump below The sump is attached to a drain system of the customers choice for recycling or disposal Do not let the oil level in the sump reach the height of the lower tubesheet where the filters rest Differential Pressure Differential pressure also referred to as pressure drop Δ P is an indication of the...

Page 9: ...eering drawings of your specific equipment and options will be provided These and all available documentation for your system should be thoroughly reviewed prior to beginning any installation work This includes the unit and electrical controls Ensure to leave an appropriate amount of room around your unit to allow for maintenance and servicing A minimum of 3 feet 1 m of clearance is recommended fo...

Page 10: ...Figure 1 for reference Ceiling mounted units are suspended by means of 1 2 threaded rods item 1 in Figure 3A which run through weld nuts item 2 in Figure 3A in the top corners of the units Refer to Figure 2 for weld nut locations on SHM models Additional support should be used for auxiliary equipment or ducting CAUTION The SMOGHOG should not be used for support of personnel or material Check with ...

Page 11: ...REV 17F SMOGHOG SHM Series Models 7 FIGURE 3B Typical Machine Mount 61 10144 ...

Page 12: ...he customers machine or a nearby wall Refer to figure 3B above for proper mounting locations and instructions Various wall mount brackets are offered and should be selected based on the desired orientation of the unit when fully assembled Left side shown right side same bracket rotated 180 and rear mounting is available ...

Page 13: ... 3 60 3065 2 1 SHM 08C A 208 3 50 60 2600 3 6 SHM 08C A 230 3 50 60 2600 4 6 SHM 08C A 380 3 50 60 2600 2 3 SHM 08C A 460 3 50 60 2600 2 8 TABLE 2 Wiring Diagrams 3 5 1 ELECTRICAL SUPPLY POWER The main power supply is connected to the SHM unit through a customer sourced sealed 1 2 conduit connector that can be installed into the 7 8 hole next to the electrical box After feeding wires through the c...

Page 14: ...REV 17F SMOGHOG SHM Series Models 10 61 10129 Figure 4 Remote Panel Touchscreen Connection ...

Page 15: ...Machine Interlock set up on the touchscreen Wiring will be terminated to the terminal blocks located in the rear electrical panel in Figure 1D When the machine dry contact is closed the SHM blower will be on and when the contact is open the SHM unit blower will shut down Note A relay coil cannot be connected to the SHM and will not work for this type of electrical circuit 3 6 FILTER INSTALLATION T...

Page 16: ...REV 17F SMOGHOG SHM Series Models 12 61 10133 Figure 5 SHM Filter Removal Installation ...

Page 17: ...cord baseline performance parameters so the system can be reset in case of an upset condition or system change The recorded data should include the static pressure at each collection hood system amperage draw and filter pressure drop at a minimum any other key pieces of data critical to your process 9 To optimize system performance and extend filter life run the unit at the minimum airflow require...

Page 18: ...ow After Filter monitoring or unique screens required for a special application These screens are based on customer order and loaded at the factory Figure 7 4 3 2 Standard Format The icon key Table 3 outlines the various icons that are used on the screen for various reasons and may indicate status or conditions The Home Settings and Information icons are shown at the bottom of most screens and wil...

Page 19: ...ween 20 and 100 This will correspond to the percentage of blower capability The blower is capable of 2 600 RPM at 100 1 950 RPM for 75 1 300 RPM for 50 and 520 RPM for 20 These numbers are approximate and may display slightly differently on any given unit There is a minimum set point for speed which is 20 for the purposes of the blower design Information Screen Figure 10 The information screen wil...

Page 20: ...tings are not password protected To select one of the items just touch the box with the item you want to make a change too The Locked Settings selection will allow the operator to select options of the system One option is Machine Interlock Process Control With Machine Interlock the operator can allow another device CNC machine center to turn the SHM on when the primary device is in operation When...

Page 21: ... Settings group on the Customer settings screen Auto Flow is an option that is selected at time of order and loaded into the SHM at the factory The Auto Flow Settings will allow the unit to maintain a precise operating point based on a desired air volume The operator will select an air volume setting in the airflow set point box using the up down arrows or the selection box If the screen is change...

Page 22: ...manual Always wear proper PPE including goggles dust mask and work gloves when installing or replacing filter elements Oil accumulated on the filter elements can result in irritation of the lungs skin and or eyes Remove used filter elements from the collector and dispose of properly in accordance with governing restrictions Be sure there is no excess oil or residue build up inside the primary filt...

Page 23: ...ist in making sure the filters are fully inserted when the door is closed and secured 5 3 CONTAMINANT REMOVAL Manual draining of the sump itself should not be necessary unless no drain is used If this is the case be sure to drain the sump regularly If a drain bottle or similar is used this should also be checked and emptied regularly Be sure oil is not accumulating in any location that could cause...

Page 24: ...ker Open rear panel on unit and switch breaker if necessary Loose or disconnected wires Inves gate wiring in the rear panel Disconnect is switched to OFF posi on Switch disconnect to ON posi on Improper source power Refer to data plate to verify required input power Screen Displayed Warning Possible Causes Recommended Solu ons Filter Cau on Filter is approaching max life Replace filter s soon Yello...

Page 25: ...T LATCH 4 42 0168 FILTER CABINET DOOR GASKET 5 42 0080 TOP PANEL WHITE PTFE GASKET NOT SHOWN 42 1549 SEALANT 10 38 10145 BULKHEAD FITTING 5 16 OD TUBING NOT SHOWN 20 1280 FLEX TUBING CLEAR 3 16 X 5 16 6 39 0258 04 FILTER CABINET DOOR HINGE PIN NOT SHOWN 39 0258 02 HINGE PIN E CLIP 7 32 10069 SHM 08C MOTORIZED IMPELLER 230 460V 7 32 10075 SHM 05C MOTORIZED IMPELLER 230 460V 8 10 14131 INLET COVER P...

Page 26: ...REV 17F SMOGHOG SHM Series Models 22 61 10134 Figure 22 ...

Page 27: ...REV 17F SMOGHOG SHM Series Models 23 A1 BASIC UNIT 04 001990 ...

Page 28: ...REV 17F SMOGHOG SHM Series Models 24 A2 REMOTE PANEL TOUCH CONTROLS 04 001802 ...

Page 29: ...REV 17F SMOGHOG SHM Series Models 25 A3 ADVANCED UNIT WITH REMOTE CONTROLS 04 002235 ...

Page 30: ...REV 17F SMOGHOG SHM Series Models 26 A4 575 480 TRANSFORMER 04 001717 ...

Page 31: ...This page intentionally left blank ...

Page 32: ... as to goods manufactured or supplied by others This warranty is subject to any limitations in UAS quotation and may not be modified except by a written instrument signed by the President or Vice President of Sales of UAS THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORALOR IMPLIED INCLUDINGANYIMPLIED WARRANTYOF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR N...

Reviews: