reV: 16i
SMoGHoG
®
SHM Series Models
17
6. TROUBLESHOOTING GUIDE
use the troubleshooting guide to correct any problems
that occur with your oil mist collection unit. if the problem
or condition continues, contact the uaS customer service
office.
all electrical/mechanical troubleshooting should be
performed by a qualified electrician/maintenance
individual familiar with uaS equipment.
Prior to troubleshooting any equipment, read the
installation and operation Manuals for each piece
of equipment to be serviced.
!
WARNING
Problem
Possible Causes
Recommended Solu�ons
Lack of air flow
Restric�on at the outlet of unit
Be sure there are no obstruc�ons in close proximity to the outlet at the top of
the unit
Inaccurate dP readings, leading to possible
auto-flow malfunc�on
Check for misaligned filters, leaks in duc�ng, leaks in plumbing, filter failure, or
transducer and connec�on failures
Blinded filters
Clean cartridge filters with a hose or other low pressure water source
Replace filter(s)
Leaking gaskets
Check for damaged gaskets and replace if necessary, careful adjustment of
latch paws may be necessary if leak persists
Restric�on or blockage in inlet duc�ng
Verify all dampers are open, duct is unobstructed
System Off
Tripped circuit breaker
Open rear panel on unit and switch breaker if necessary
Loose or disconnected wires
Inves�gate wiring in the rear panel
Disconnect is switched to OFF posi�on
Switch disconnect to ON posi�on
Improper source power
Refer to data plate to verify required input power
Screen Displayed Warning
Possible Causes
Recommended Solu�ons
Filter Cau�on
Filter is approaching max life
Replace filter(s) soon
(Yellow)
Restric�on in dP readings
Check for kinked tubing, obstructed pressure taps
Filter Warning
Filter has surpassed max life
Replace filter(s)
(Red)
Blinded filters
Clean cartridge filters with a hose or other low pressure water source
Replace filter(s)
Pressure taps obstructed
Check and clear pressure taps in the unit
Pressure tubing is kinked or plugged
Check and clear all tubing in the unit
Blower Warning*
Improper source power
Refer to data plate to verify required input power
(Red)
Phase loss
Check for loose/disconnected wires, shorts, or tripped circuit breakers
Motor over-temp.
Shut system off (if not already) and allow motor to cool. If issue repeats,
contact a UAS rep.
Auto-flow set point cannot be reached
Verify auto-flow value is set properly, check filter(s) for replacement
Reduce sta�c pressure in system
Refer to "Lack of air flow" sec�on above
Other
Contact a UAS representa�ve for assistance
*Always refer ini�ally to the fault screen displayed on the unit
Troubleshoo�ng Guide
Total system sta�c pressure exceeds blower
capability
Summary of Contents for SMOGHOG SHM-11C
Page 1: ...Model SHM 11C Shown SMOGHOG Media Mist Collector l Models SHM C SHM F OWNER S MANUAL ...
Page 11: ...REV 16I SMOGHOG SHM Series Models 7 61 10126 Figure 4 Remote Panel Touchscreen Connection ...
Page 23: ...REV 16I SMOGHOG SHM Series Models 19 Figure 6 SHM Replacement Parts SHM 11C SHM 11F ...
Page 24: ...REV 16I SMOGHOG SHM Series Models 20 APPENDIX WIRING DIAGRAMS BASIC CONTROLS A1 04 001682 ...
Page 25: ...REV 16I SMOGHOG SHM Series Models 21 A2 REMOTE PANEL BASIC CONTROLS 04 001799 ...
Page 26: ...REV 16I SMOGHOG SHM Series Models 22 A3 ONE BLOWER AND CONTROLS 04 001695 ...
Page 27: ...REV 16I SMOGHOG SHM Series Models 23 A4 TWO BLOWER AND CONTROLS 04 001696 ...
Page 28: ...REV 16I SMOGHOG SHM Series Models 24 A5 THREE BLOWER AND CONTROLS 04 001697 ...
Page 29: ...REV 16I SMOGHOG SHM Series Models 25 A6 REMOTE PANEL TOUCH CONTROLS 04 001802 ...
Page 30: ...REV 16I SMOGHOG SHM Series Models 26 A7 ONE BLOWER AND REMOTE CONTROLS 04 001798 ...
Page 31: ...REV 16I SMOGHOG SHM Series Models 27 A8 TWO BLOWER AND REMOTE CONTROLS 04 001797 ...
Page 32: ...REV 16I SMOGHOG SHM Series Models 28 A9 THREE BLOWER AND REMOTE CONTROLS 04 001796 ...
Page 33: ...REV 16I SMOGHOG SHM Series Models 29 A10 575 480 TRANSFORMER 04 001717 ...
Page 34: ...This page intentionally left blank ...