reV: 16i
SMoGHoG
®
SHM Series Models
5
3.4 MECHANICAL INSTALLATION
CRUSH HAZARD
use adequate safety measures when lifting and
assembling any heavy components. consult your
plant safety personnel for recommendations.
connect lifting slings and spreader bars to lifting lugs
with clevis pins. use spreader bars to distribute the
load evenly. Location must be clear of all obstructions,
such as utility lines or roof overhangs.
When the SHM unit is to be
mounted directly to a
machine
, you will be furnished with a mounting flange and
drawing to illustrate the bolt pattern and hardware required
for proper mounting to their equipment. Be sure to seal
around the entire perimeter between the mounting flange
and the existing machine with an appropriate sealant in a
figure-eight pattern around each bolt hole.
units with
sumps
utilize 10˝ inlets and optional collar
flange(s) that come mounted to the unit. they can be
rearranged and mounted however desired based on
application needs. Be sure to use a polyurethane sealant
or gasket to prevent leaks. it is recommended to use
ducting that is liquid tight to prevent leaks.
all other transitions, ducting or plenums required for
unit set-up and operation are not included with the
equipment.
unit should always be secured to the floor when
installed in this configuration.
Secure the unit at all four corners using the standard
unit feet or extension leg foot pads. At least one of the
two holes per foot pad on the extension legs should be
secured. See figure 1 for reference.
Ceiling mounted
units are suspended by means of 1⁄2˝
threaded rods (item #1 in figure 3) which run through
weld nuts (item #2 in figure 3) in the top corners of the
units. refer to figure 2 for weld nut locations on SHM-11
models. Additional support should be used for auxiliary
equipment or ducting. do not suspend units larger than
the SHM-11 from the ceiling.
CAUTION
the SMoGHoG should not be used for support of
personnel or material. check with local building code/
structural engineer to ensure proper installation to roof
truss or any other mounting method.
Metal Truss Supported Ceilings.
figure 3 shows an
SHM-11 unit suspended from a metal truss supported
ceiling. customer should take care to determine that the
truss will be sufficient to support the weight. as shown,
angle iron braces are secured between two steel trusses.
rod length should be kept to a minimum and cut to length
as necessary.
FIGURE 3
Ceiling Mounted Unit
in this instance, the rods instead will be installed in the
exact same fashion into the weld nuts found in the blower
cabinet.
Be sure rods are threaded adequately into weld nuts,
about 1˝ (25.4 mm) of rod extending inside the cabinet is
acceptable.
tighten lock nuts (item #3 in figure 3) in place to be sure
unit does not vibrate lose or fall over time.
!
D A N G E R
CAUTION
Summary of Contents for SMOGHOG SHM-11C
Page 1: ...Model SHM 11C Shown SMOGHOG Media Mist Collector l Models SHM C SHM F OWNER S MANUAL ...
Page 11: ...REV 16I SMOGHOG SHM Series Models 7 61 10126 Figure 4 Remote Panel Touchscreen Connection ...
Page 23: ...REV 16I SMOGHOG SHM Series Models 19 Figure 6 SHM Replacement Parts SHM 11C SHM 11F ...
Page 24: ...REV 16I SMOGHOG SHM Series Models 20 APPENDIX WIRING DIAGRAMS BASIC CONTROLS A1 04 001682 ...
Page 25: ...REV 16I SMOGHOG SHM Series Models 21 A2 REMOTE PANEL BASIC CONTROLS 04 001799 ...
Page 26: ...REV 16I SMOGHOG SHM Series Models 22 A3 ONE BLOWER AND CONTROLS 04 001695 ...
Page 27: ...REV 16I SMOGHOG SHM Series Models 23 A4 TWO BLOWER AND CONTROLS 04 001696 ...
Page 28: ...REV 16I SMOGHOG SHM Series Models 24 A5 THREE BLOWER AND CONTROLS 04 001697 ...
Page 29: ...REV 16I SMOGHOG SHM Series Models 25 A6 REMOTE PANEL TOUCH CONTROLS 04 001802 ...
Page 30: ...REV 16I SMOGHOG SHM Series Models 26 A7 ONE BLOWER AND REMOTE CONTROLS 04 001798 ...
Page 31: ...REV 16I SMOGHOG SHM Series Models 27 A8 TWO BLOWER AND REMOTE CONTROLS 04 001797 ...
Page 32: ...REV 16I SMOGHOG SHM Series Models 28 A9 THREE BLOWER AND REMOTE CONTROLS 04 001796 ...
Page 33: ...REV 16I SMOGHOG SHM Series Models 29 A10 575 480 TRANSFORMER 04 001717 ...