Service Bulletin
25
UAV-1005757-001 Rev A
4.
Click the left button under “Done” when completed. Once successfully
completed the red
“NOMAG” flag will extinguish. If the calibration
failed, please complete again. The AV-30 will retain all calibration
unless a hard reset is accomplished.
10 System Checkout
P
erform the System Checkout procedure as described in “AV-30-E
Installation Manual” UAV-1004234-001 Section 13.2 prior to returning to
service.
11 Support
For additional questions or support please visit:
http://www.uavionix.com/support/