80
Ubiflux F300 / F300+
Ubiflux F300 / F300+
81
GB
STEP NO. ODESCRIPTION
FACTORY SETTING
UBIFLUX
F300
IADJUSTING RANGE
STEP
01
Air flow rate mode /
50 m
3
/h
0 m
3
/h of 50 m
3
/h
02
Air flow rate mode 1 /
100 m
3
/h
50 m
3
/h t/m 300 m
3
/h
5 m
3
/h
03
Air flow rate mode 2 /
150 m
3
/h
50 m
3
/h t/m 300 m
3
/h
5 m
3
/h
04
Air flow rate mode 3 /
225 m
3
/h
50 m
3
/h t/m 300 m
3
/h
5 m
3
/h
05
Bypass temperature
22,0 °C
15,0 °C - 35,0 °C
0,5 °C
06
Bypass hysterese
2,0 °C
0,0 °C - 5,0 °C
0,5 °C
07
Operation bypass valve
0
0 (= Automatic)
1 (= Bypass valve closed)
2 (= Bypass valve open)
8
Central h
heat recovery
OFF
OFF (=Central heat recovery off)
ON (= Central heat recovery on)
9
Imbalance permissible
ON
OFF (= flow rate supply equals extract)
ON (= imbalance permissible)
10
Fixed imbalance
0 m
3
/h
-100 m
3
/h t/m 100 m
3
/h
1 m
3
/h
11
Preheater connected
OFF
ON (= preheater connected)
OFF (= no preheater)
STEP NO. DESCRIPTION
FACTORY SETTING
UBIFLUX F300+
ADJUSTING RANGE
STEP
12
Heater
0
0 (= no additional heater)
1 (= additional preheater)
2 (= postheaterr)
13
Temperature postheater
21,0 °C
15,0 °C t/m 30,0 °C
0,5 °C
14
Selection input 1
OFF
OFF ( = switching input 1 active)
ON (= 0 - 10 volt input 1 active)
15
Minimum voltage input 1
0,0 V
0 Volt - 10 Volt
0,5 V
16
Maximum voltage input 1
10,0 V
0 Volt - 10 Volt
0,5 V
17
Conditions
switching input 1
0
0 (off)
1 (on)
2 (= On if conditions bypass
open satisfied)
3 (= Bypass control)
4 (= Bedroom valve)
18
Supply fan mode
switching input 1
5
0 (= Input fan off)
1 (= Absolute min. flow rate 50m
3
/h)
2 (= Flow rate mode 1)
3 (= Flow rate mode 2)
4 (= Flow rate mode 3)
5 (= Multiple switch 6 (= Maximum
flow rate)
12
Instelwaarden / Setting values
Einstellwerte / Valeurs de réglage