8
Ubiflux W450
Supply voltage [V/Hz]
230/50
Protection degree
IP30
Dimensions (w x h x d) [mm]
677 x 765 x 564
Duct diameter [mm]
Ø180
External diameter condensate discharge [mm]
Ø32
Weight [kg]
38
Filter class
G3 (F7 optional for supply)
Fan setting (factory setting))
1
2
3
Ventilation capacity [m
3
/h]
50
100
200
300
Permissible resistance ducts system [Pa]
2 - 5
5 - 15
20 - 60
40 - 130
Rated power (excl. preheater)[W]
9,5
11 - 18
32 - 45
80 - 105
Rated current (excl. preheater)[A]
0,10
0,10 - 0,18
0,30 - 0,46
0,70 - 0,95
Max. rated current (with preheater switched on) [A]
6
Cos φ
0,43
0,43 - 0,45
0,43 - 0,45
0,48 - 0,50
Ubiflux W450
Ventilation capacity [m
3
/h]
100
200
225
300
400
Sound power
level Lw (A)
Static pressure [Pa]
9
40
38
80
47
100
84
175 240 150 225
Housing emission [dB(A)
29.5 32.5 40.5 40.5 43.5 47.5 51.0 53.0 54.0 54.5 57.0
Duct “from dwelling” [dB(A)]
31.5 34.5 46.5 48.0 48.5 50.0 56.5 57.0 58.0 59.0 60.0
Duct “to dwelling” [dB(A)]
42.5 47.5 57.0 59.0 60.5 62.5 66.0 68.5 69.5 70.5 71.5
In practice, the value may deviate 1 dB(A) as a result of measuring tolerances