22
Ubiflux W300(+) / W400(+) / W450(+)
Ubiflux W300(+) / W400(+) / W450+
23
The readout menu can be used to call up a number of
current sensor values to obtain more information on
the appliance's performance. Modifying values of set
-
tings is
not
possible in the readout menu. The
readout
menu
can be displayed as follows.
1. In operating mode, press the ‘
MENU
’ key. Now the display
shows the
settings menu
.
2. Use the ‘
+
’ and the ‘
-
’ key to go to the
readout menu
.
3. Activate the
readout menu
.
4 Use the ‘
+
’ and the ‘
-
’ key to scroll through the rear menu.
5 Press the ‘
R
’ key twice to go back to operating mode.
If no key is operated during 5 minutes, the appliance auto
-
matically returns to operating mode.
6.4 Readout menu
Step no. readout
value
Description readout value
Unit
01
Current temperature from dwelling
°C
02
Current temperature outdoors sensor
o
C
03
Bypass status (ON = bypass valve open, OFF = bypass valve closed)
04
Status frost protection (ON = frost protection active, OFF = frost protection not active)
05
Current channel pressure supply
Pa
06
Current duct pressure extract
Pa
07
Current air flow rate supply fan
m
3
/h
08
Current air flow rate extract fan
m
3
/h
09
Actual relative humidity (+ version)
%
readout value
Step no. readout value;
refer to the table below
for an explanation
2 x
Chapter 6
Display
readout menu
settings menu
operating mode
operating mode