41
Ubiflux W300(+) / W400(+) / W450(+)
Ubiflux W300(+) / W400(+) W450(+)
42
41
Ubiflux W300(+) / W400(+) / W450(+)
Chapter 13
Setting values
STEP
NO. DESCRIPTION
FACTORY
SETTING
ADJUSTING RANGE
STEP DISPLAY TEXT +
SYMBOLS
01
Air flow rate Ubiflux W300 : mode
50 m
3
/h
0 m
3
/h or 50 m
3
/h
Air flow rate Ubiflux W400 : mode
50 m
3
/h
0 m
3
/h or 50 m
3
/h
Air flow rate Ubiflux W450 : mode
50 m
3
/h
0 m
3
/h or 50 m
3
/h
02
Air flow rate Ubiflux W300 : mode 1
100 m
3
/h
50 m
3
/h - 300 m
3
/h
5 m
3
/h
Air flow rate Ubiflux W400 : mode 1
100 m
3
/h
50 m
3
/h - 400 m
3
/h
Air flow rate Ubiflux W450 : mode 1
100 m
3
/h
50 m
3
/h - 450 m
3
/h
03
Air flow rate Ubiflux W300 : mode 2
150 m
3
/h
50 m
3
/h - 300 m
3
/h
5 m
3
/h
Air flow rate Ubiflux W400 : mode 2
200 m
3
/h
50 m
3
/h - 400 m
3
/h
Air flow rate Ubiflux W450 : mode 2
200 m
3
/h
50 m
3
/h - 450 m
3
/h
04
Air flow rate Ubiflux W300 : mode 3
225 m
3
/h
50 m
3
/h - 300 m
3
/h
5 m
3
/h
Air flow rate Ubiflux W400 : mode 3
300 m
3
/h
50 m
3
/h - 400 m
3
/h
Air flow rate Ubiflux W450 : mode 3
300 m
3
/h
50 m
3
/h - 450 m
3
/h
05
Bypass temperature
22,0 °C
15,0 °C - 35,0 °C
0,5 °C
BYPASS
06 Bypass hysterese
2,0 °C
0,0 °C - 5,0 °C
0,5 °C
BY HYS
07 Operation bypass valve
0
0 (=
Automatic
)
1 (=
Bypass valve closed)
2 (=
Bypass valve open)
BYPASS
08
Communication
eBUS
Ot ( = Opentherm)
eBUS
OT/BUS
09
Bus address
0
0 - 9 (0 = Master)
BUSADR
10
Central h
heat recover
OFF
OFF (=
Central heat rec. off
)
ON (=
Central heat rec. on
)
CV+WTW
11 Imbalance permissible
ON
OFF (=
flow rate sup. equals extract
)
ON (=
imbalance permissible)
12
Fixed imbalance
0 m
3
/h
-100 m
3
/h t/m 100 m
3
/h
1 m
3
/h
STEP
NO. DESCRIPTION
FACT. SETTINGS
REN. EXC. “+”
ADJUSTING RANGE
STEP
DISPLAY TEXT +
SYMBOLS
13 Heater
0
0 (= off)
1 (= preheater)
2 (= postheater)
HEATER
14
Temperature postheater
21,0 °C
15,0 °C - 30,0 °C
0,5 °C
HEATER
15
Selection input 1
0
0 (= normally open contact)
1 (= 0 - 10V input)
2 (= normally closed contact)
3 (= input 1/ bypas open
12V;
bypass closed
0V)
4 (= input 1/ bypas open
0V;
bypass closed
12V)
V1
16
Minimum voltage input 1
0,0 V
0 Volt - 10 Volt
0,5 V
V1 MIN
17
Maximum voltage input 1
10,0 V
0 Volt - 10 Volt
0,5 V
V1 MAX
18 Conditions
switching input 1
0
0 (off)
1 (on)
2 (= On if conditions bypass
open satisfied)
3 (= Bypass control)
4 (= Bedroom valve)
CN1
19
Supply fan mode
switching input 1
5
0
(= Input fan off)
1
(= Absolute min. flow rate 50m
3
/h)
2 (= Flow rate mode 1)
3 (= Flow rate mode 2)
4 (= Flow rate mode 3)
5
(= Multiple switch
6
(= Maximum flow rate)
7 (= no fan activation)
CN1