Other features
Glows when the bucket is ready to be
emptied, or when the bucket is removed
or not replaced in the proper position.
8
Display
Shows the set % humidity level from 35% to 85% or auto start/stop time (0~24) while setting,
±
5% accuracy) room % humidity level in a range of 30% RH (Relative
Error Codes and Protection Codes
AS- Humidity sensor error--Unplug the unit and plug it back in. If error repeats, call for service.
ES- Temperature sensor error--U
nplug t he u nit a nd p lug i t b ack i n.If e rror r epeats,ca ll fo r se rvice.
P2- Bucket is full or bucket is not in correct position-- Empty the bucket and replace it in the right
position.
E1- Unit malfunction-- Unplug the unit and plug it back in. If error repeats, call for service.
CONTROL PADS ON THE DEHUMIDIFIER
Bucket Full Light
Auto Shut Off
Auto Defrost
when frost builds up on the evaporator coils. The
compressor will cycle off and the fan will continue
to run until the frost disappears, and the light will
be off.
seconds when the bucket is full, or when the
bucket is removed or not replaced in the proper
position. When the setting humidity is reached,
the unit will shut off automatically. For some
models, the fan motor will continue operating
then shows the actual (
When the unit is on, first press the Timer
pad, the Timer Off indicator light
illuminates. It indicates the Auto Stop
program is initiated. Press Timer pad again-the
Time On indicator light illuminates.It
indicates the Auto Start is initiated.
When the unit is off, first press the Timer
pad, the TIMER ON indicator light
illuminates. It indicates the Auto Start
program is initiated. Press the pad again-the
Time Off indicator light illuminates.It
indicates the Auto Stop is initiated.
Press or hold the UP or DOWN pad to
change the Auto time in 0.5 hour incre-
ments, up to 10 hours, then in 1 hour
increments up to 24 hours. The control
will count down the time remaining until
start.
The selected time will register in 5 seconds
and the system will automatically revert
back to display the previous humidity
setting.
When the Auto start & Auto stop times are
set, within the same program sequence,
TIMER ON/OFF indicator lights illuminate
identifying both ON and OFF times are
now programmed.
Turning the unit ON or OFF at any time or
adjusting the timer setting to 0.0 will cancel
the Auto Start/Stop function.
When LED display window displays P2 code,
the
cancelled.
Auto Start/Stop function will also be
Setting the Timer
Wait 3 minutes before resuming operation
Check filter feature
Auto-Restart (on some models)
when the power resumes.
The system starts to count the time once the fan
motor operates. The check filter feature can only be
activated when the accumulated operation time reach
250 hours or more.
Clean filter indicator light flashes
at one time per second, after finishing clean the air
filter, press the Filter pad and Clean filter indicator
light goes off.
operation in the first 3 minutes. This feature protects
the unit. Operation will automatically start after
3 minutes.
After the unit has stopped, it cannot restart its
Humidity) to 90% RH (Relative Humidity).
5
The dehumidifier shuts off completely after 30
The Auto defrost indicator light will illuminate
If the unit stops unexpectedly due to a loss of power,
it will restart automatically with its previous settings