18
UBI EasyCoder 501 – Technical Manual
1
/. “Default” refers to the default setup values in the standard configuration EPROM's. A custom-made printer fitted with
non-standard configuration EPROM's may have a different combination of default setup values.
2
/. The software is able to detect if any optional serial interface board is fitted. If so, the serial communication parameters
and the size of the communication buffers are set up separately for each of the communication channels "uart1:", "uart2:",
and "uart3:". There is no communication setup for the optional Centronics parallel communication channel.
3
/. Baudrate 38400 is only available for "uart2:" and "uart3:" (requires an optional interface board).
4
/. In EasyCoder 501 printers without a thermal transfer mechanism, the default paper option is RICOH 130LAB/LAM.
5
/. Not available for EasyCoder 501.
6
/. Higher default value for EasyCoder 501 SA.
The setup allows you to adapt the printer for the desired type of
computer communication and to control the printing. The setup
parameters are:
General Information
Parameter
Options
Default
1
❑
Contrast
Variable (0–10)
Middle (5)
❑
Ser-Com
2
:
◆
Baudrate
300 | 600 | 1200 | 2400 | 4800 | 9600 | 19200 | 38400
3
9600
◆
Parity
even | odd | mark | space | none
none
◆
Char length
7 bits | 8 bits
7 bits
◆
Stop bits
1 bit | 2 bits
2 bits
◆
Flow control:
- RTS/CTS
Enable | disable (not on "uart2:" when RS 485 interface pcb fitted)
disable
- ENQ/ACK
Enable | disable
disable
- XON/XOFF, data from host
Enable | disable
enable
- XON/XOFF, data to host
Enable | disable
enable
- Prot addr.
Enable | disable ("uart2:"on RS 485 interface pcb only)
disable
◆
New line
CR/LF | LF | CR
CR/LF
❑
Detection
:
◆
LSS adjust
Variable
n.a.
◆
Feedadj:
- Startadj
Variable
±
0
- Stopadj
Variable
±
0
❑
Service
:
◆
Media size:
- X-start
Variable (8 dots/mm: 0 – 831; 11.81 dots/mm: 0–1279)
0/0
- Width
Variable (8 dots/mm: 0 – 832; 11.81 dots/mm: 0–1280)
832/1280
- Length
Unlimited
1200/1200
◆
Media type:
Label (w gaps) | Ticket (w mark) | Ticket (w gaps) |
Fix length strip | Var length strip
Label (w gaps)
◆
Print defs:
- Head resist
Set automatically at startup
n.a.
- Paper type
Select supply option. See chapter “Selecting Paper/Ribbon”
UBI HP 20
4
- New supplies
Select a new type of supply by means of a 13-digit code
n.a.
- Testprint
A series of test labels can be printed
5
n.a.
◆
Performance
5
:
Normal | High | Ultrahigh
Normal
◆
Memory alloc:
- Image buff size
Variable (max. 250 kbyte)
48 kbyte
6
- Rec buf size
2
Variable
300 byte
6
- Trans buf size
2
Variable
300 byte
SETUP PARAMETERS