Getting to Know the Power Station
Smart Screen LCD
Getting to Know the Power Station
Error Messages
1. High battery temperature
Displays when internal battery pack
reaches temperature over 113° F when
charging, and 140° when discharging.
It is recommended that you unplug
devices, power off, and allow to cool
for 30-60 minutes.
4. Internal short
Displays when a internal short circuit
has occurred. The built-in circuit
breaker will cut off power to the
device in the event of a short circuit.
To reset the circuit breaker, power
down the device, wait 30 seconds and
power it back on.
2. High internal temperature
Displays when the internal AC inverter
reaches a temperature of 167° F. It
is recommended that you unplug
devices, power off, and allow to cool
for 30-60 minutes.
3. High output
Displays when a device is plugged in
that exceeds the recommended output
of the power station. The device
plugged in is drawing too much power.
Unplug high wattage devices.