3.  Position the EdgeSwitch with the Ethernet ports facing 

down. Place the wall‑mount slots of the EdgeSwitch over 
the screw heads on the wall. Then slide the EdgeSwitch 
down to lock it into place.

Grounding the EdgeSwitch (Recommended)

The EdgeSwitch is grounded through the Power Adapter
however, you can add optional ESD grounding for enhanced 
ESD protection.
1.  Attach the Ground Screw to secure a ground wire (not 

included) to the Grounding Point.

2.  Optional: To secure the Power Adapter cord, insert it 

into the Cable Clip and secure the Cable Clip using the 
Ground Screw.

3.  Secure the other end of the ground wire to a grounding block.

Summary of Contents for 0817882025218

Page 1: ...8 Port Gigabit Switch with PoE and 2 SFP Ports Model ES 10XP ...

Page 2: ...r use For outdoor applications shielded Category 5 or above cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the power supply We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial grade shielded Ethernet cable from Ubiquiti Networks For more details visit www ubnt com toughca...

Page 3: ...ons If you use a copper Ethernet module example UF RJ45 1G power off the EdgeSwitch before insertion otherwise there may be a device reboot Front Panel Button Reset Button Description Reset To reset to factory defaults 1 Disconnect power from the EdgeSwitch 2 Reconnect power while holding the Reset button The port LEDs will light up in sequential order this takes approximately five seconds 3 When ...

Page 4: ...Ready for Use Not Connected to Ubiquiti Network Management System UNMS Blue Ready for Use Connected to UNMS Steady Blue with Occasional Flashing Ready for Use Unable to Connect to UNMS Quickly Flashing Blue Used to Locate a Device in UNMS Alternating Blue White Firmware Upgrade in Progress ...

Page 5: ...nk Activity Off No Link Amber Link Established at 10 100 Mbps Amber Flashing Link Activity at 10 100 Mbps Green Link Established at 1000 Mbps Green Flashing Link Activity at 1000 Mbps SFP LEDs Link Activity LED State Status Link Activity Off No Link Green Link Established at 1 Gbps Green Flashing Link Activity at 1 Gbps ...

Page 6: ...er Grounding Point Interface Description Power Connect the included Power Adapter to the Power port Grounding Point Ground bonding point for an optional ground wire Side Panel Ventilation Holes Bracket Mounting Holes ...

Page 7: ...HE VENTILATION HOLES FOR ADEQUATE AIRFLOW WARNING The EdgeSwitch ES 10XP must not be stacked Do not place it on top of another switch Do not place anything on top of the ES 10XP Wall Mounting To mount the EdgeSwitch on a wall you will need a drill a 6 mm drill bit and a Phillips screwdriver 1 Use a 6 mm drill bit to drill two holes 148 mm apart 2 Insert the Wall Mount Anchors into the holes Use a ...

Page 8: ...witch Recommended The EdgeSwitch is grounded through the Power Adapter however you can add optional ESD grounding for enhanced ESD protection 1 Attach the Ground Screw to secure a ground wire not included to the Grounding Point 2 Optional To secure the Power Adapter cord insert it into the Cable Clip and secure the Cable Clip using the Ground Screw 3 Secure the other end of the ground wire to a gr...

Page 9: ...Connecting Power 1 Connect the Power Adapter to the Power port 2 Connect the Power Cord to the Power Adapter 3 Connect the other end of the Power Cord to a power outlet ...

Page 10: ...necting Ethernet 1 Connect an Ethernet cable from your DHCP server or LAN system to any port on the EdgeSwitch 2 Connect your computer or host system and other devices to the other ports on the EdgeSwitch ...

Page 11: ...compatible fiber module into the SFP port 100 0M bp s SM SC 20K M DD M Tx1 550 nm Rx 131 0nm 3 Connect the fiber optic cable to the fiber module Then connect the other end of the cable to another fiber device For information about compatible fiber SFP modules visit ubnt link SFP_DAC_Compatibility ...

Page 12: ...e label Let the EdgeSwitch obtain an IP address and then check the DHCP server to see which IP address was assigned To log in follow these steps 1 Launch your web browser Type the appropriate IP address in the address field Press enter PC or return Mac 2 The login screen will appear Enter ubnt in the Username and Password fields Click Sign In The EdgeSwitch Configuration Interface will appear Cust...

Page 13: ...ch your web browser Type the appropriate IP address in the address field 192 168 1 20 is the default fallback IP address Press enter PC or return Mac https 192 168 1 20 4 The login screen will appear Enter ubnt in the Username and Password fields Click Sign In When you sign in you agree to accept the Ubiquiti License Agreement 5 The EdgeSwitch Configuration Interface will appear Click the System S...

Page 14: ...ation Interface will appear Customize additional settings as needed For 24V Passive PoE configuration refer to Configuring PoE Settings For more information refer to the EdgeSwitch documentation which is available at www ubnt com download edgemax UNMS Management You can manage your device using UNMS which lets you configure monitor upgrade and back up your devices using a single application Get st...

Page 15: ...lt WARNING Before activating PoE ensure that the connected device supports passive PoE and the supplied voltage 1 On the Dashboard tab click the PoE setting of the Ethernet port you want to configure Then select 24V 2 The Ethernet port s PoE LED will confirm the PoE setting PoE ...

Page 16: ...r Included LEDs System RJ45 Data Ports SFP Data Ports Status PoE Link Speed Activity Link Activity Networking Interfaces 8 10 100 1000 Mbps RJ45 Ports 2 1 Gbps SFP Ports Management Interface Ethernet In Band Certifications CE FCC IC ESD EMP Protection Air 24 kV Contact 24 kV Operating Temperature 10 to 50 C 14 to 122 F Operating Humidity 5 to 95 Noncondensing Shock and Vibration ETSI300 019 1 4 St...

Page 17: ... hazard if the limitations are not followed 2 There are no operator serviceable parts inside this equipment Service should be provided only by a qualified service technician 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet a Do not substitute the power cord with one that is not the provided approv...

Page 18: ... A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Op...

Page 19: ...ent please contact your local authorities waste disposal service or the shop where you purchased the product Deutsch Die Europäische Richtlinie 2012 19 EU verlangt dass technische Ausrüstung die direkt am Gerät und oder an der Verpackung mit diesem Symbol versehen ist nicht zusammen mit unsortiertem Gemeindeabfall entsorgt werden darf Das Symbol weist darauf hin dass das Produkt von regulärem Haus...

Page 20: ...que tout autre matériel électrique ou électronique par les moyens de collecte indiqués par le gouvernement et les pouvoirs publics des collectivités territoriales L élimination et le recyclage en bonne et due forme ont pour but de lutter contre l impact néfaste potentiel de ce type de produits sur l environnement et la santé publique Pour plus d informations sur le mode d élimination de votre anci...

Page 21: ...ab et antud ES 10XP seade on vastavus olulistele nõuetele ja teistele asjakohastele sätetele direktiivide 2014 30 EL 2014 35 EL ELi vastavusdeklaratsiooni täielik tekst on kättesaadav järgmisel internetiaadressil www ubnt com compliance Suomi Finnish Täten UBIQUITI NETWORKS vakuuttaa että tämä ES 10XP laite on yhdenmukainen olennaisten vaatimusten ja muiden sitä koskevien direktiivien 2014 30 EU 2...

Page 22: ...tuguese UBIQUITI NETWORKS declara que este dispositivo ES 10XP está conforme com os requisitos essenciais e outras disposições das Directivas 2014 30 UE 2014 35 UE O texto integral da declaração de conformidade está disponível no seguinte endereço de Internet www ubnt com compliance Română Romanian Prin prezenta UBIQUITI NETWORKS declară că acest dispozitiv ES 10XP este în conformitate cu cerințel...

Page 23: ...eMAX EdgeOS EdgeRouter EdgeSwitch TOUGHCable and UNMS are trademarks or registered trademarks of Ubiquiti Networks Inc in the United States and in other countries All other trademarks are the property of their respective owners JL010919 w w w u b n t c o m Ubiquiti Networks Inc 685 Third Avenue 27th Floor New York NY 10017 USA ...

Reviews: