Chapter 10: Tools
Each tab of the airFiber Configuration Interface contains
network administration and monitoring tools. Click the
Tools
drop‑down list at the top right corner of the page.
Align Antenna
Use the
Align Antenna
tool to point and optimize the
antenna in the direction of maximum link signal. The
Antenna Alignment
window is designed to refresh every
250 milliseconds.
Chain 0/1 (Actual/Ideal)
Displays the absolute power
level (in dBm) of the received signal for each chain.
Note:
If “Overload” is displayed to indicate an
overload condition, identify and eliminate any
sources of strong in‑band interference.
Remote Chain 0/1 (Actual/Ideal)
Displays the absolute
power level (in dBm) of the received signal for each chain
of the remote airFiber X radio.
Max Signal
Displays the maximum signal strength (in
dBm). To adjust the range of the
Max Signal
meter, use
the slider or manually enter the new value. If you reduce
the range, the color change will be more sensitive to
signal fluctuations, indicating the offset of the maximum
indicator value and the scale itself.