background image

18/09/2020

GBE-LR Quick Start Guide

https://dl.ui.com/qsg/GBE-LR/GBE-LR_EN.html

21/23

improper operation, damage to the equipment or pose a  re hazard if the limitations are not

followed.

2. There are no operator serviceable parts inside this equipment. Service should be provided only by a

quali ed service technician.

3. This equipment is provided with a detachable power cord which has an integral safety ground wire

intended for connection to a grounded safety outlet.

a. Do not substitute the power cord with one that is not the provided approved type. Never use an

adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding

wire.

b. The equipment requires the use of the ground wire as a part of the safety certi cation,

modi cation or misuse can provide a shock hazard that can result in serious injury or death.

c. Contact a quali ed electrician or the manufacturer if there are questions about the installation

prior to connecting the equipment.

d. Protective earthing is provided by Listed AC adapter. Building installation shall provide

appropriate short-circuit backup protection.

e. Protective bonding must be installed in accordance with local national wiring rules and

regulations.

Limited Warranty

ui.com/support/warranty

The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and,

where applicable, specify arbitration instead of jury trials or class actions.

Compliance

FCC / CAN ICES-3(A)/NMB-3(A)

Changes or modi cations not expressly approved by the party responsible for compliance could void

the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules and ISED Canada licence-exempt RSS standard(s).

Operation is subject to the following two conditions.

1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired

operation.

Le présent appareil est conforme aux CNR d’ISDE Canada applicables aux appareils radio exempts de

licence. L’exploitation est autorisée aux deux conditions suivantes :

1. l’appareil ne doit pas produire de brouillage;
2. l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible

d’en compromettre le fonctionnement.

This equipment has been tested and found to comply with the limits for a Class A digital device,

pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against

harmful interference when the equipment is operated in a commercial environment. This equipment

generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance

with the instruction manual, may cause harmful interference to radio communications. Operations of

this equipment in a residential area is likely to cause harmful interference in which case the user will be

required to correct the interference at his own expense.
This radio transmitter FCC ID: SWX-GBELR / IC: 6545A-GBELR has been approved by FCC / ISED Canada.

GBE-LR Quick Start Guide

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for GBE-LR

Page 1: ...h Main Arm Stabilizer Arms Qty 2 Mounting Bracket Screw U Clamp Flat Washers Qty 2 Lock Washers Qty 2 Flange Nuts Qty 2 Gigabit PoE 24V 0 5A with Mounting Bracket Power Cord Package Contents GBE LR Qu...

Page 2: ...bling and shielded RJ45 connectors are required for all wired Ethernet connections Surge protection should be used for all outdoor installations We recommend that you use two Ethernet Surge Protectors...

Page 3: ...Lights steady blue when the 60 GHz link is ready Lights steady blue when the 5 GHz link is ready The LED will light steady blue when an active Ethernet connection is made to the Ethernet port and ash...

Page 4: ...Flashing Blue Used to locate a device in UNMS Alternating Blue White Firmware upgrade in progress This Gigabit Ethernet port is used to connect the power and should be connected to the LAN and DHCP s...

Page 5: ...Guide https dl ui com qsg GBE LR GBE LR_EN html 5 23 3 OPTIONAL Attach the stabilizer arms for added support This is recommended for long range installations GBE LR Quick Start Guide All manuals and...

Page 6: ...R_EN html 6 23 4 Note The GBE LR can mount on either side of the pole This section shows the GBE LR mounted on the left the procedure for mounting on the right is similar OR GBE LR Quick Start Guide A...

Page 7: ...ick Start Guide https dl ui com qsg GBE LR GBE LR_EN html 7 23 Left Right 5 Note Rotate the Mounting Bracket clockwise until it locks into position 6 GBE LR Quick Start Guide All manuals and user guid...

Page 8: ...18 09 2020 GBE LR Quick Start Guide https dl ui com qsg GBE LR GBE LR_EN html 8 23 7 8 GBE LR Quick Start Guide All manuals and user guides at all guides com...

Page 9: ...18 09 2020 GBE LR Quick Start Guide https dl ui com qsg GBE LR GBE LR_EN html 9 23 Pole not shown 9 10 GBE LR Quick Start Guide All manuals and user guides at all guides com...

Page 10: ...18 09 2020 GBE LR Quick Start Guide https dl ui com qsg GBE LR GBE LR_EN html 10 23 11 12 13 GBE LR Quick Start Guide All manuals and user guides at all guides com...

Page 11: ...ui com qsg GBE LR GBE LR_EN html 11 23 Connecting Power WARNING The switch port must comply with the power speci cations listed in Speci cations OR GBE LR Quick Start Guide All manuals and user guide...

Page 12: ...ide a speci c IP address to the device based on its MAC address on the label Let the device obtain an IP address and then check the DHCP server to see which IP address was assigned 1 Connect a compute...

Page 13: ...evice enable Access Point mode For the other device the Station keep Access Point disabled b Enter a name in the SSID eld This must be the same on both the AP and the Station c In the WPA2 Preshared K...

Page 14: ...this option to disable the DHCP client and enter a static IP address c Click Save Changes Fallback IP Address 1 Ensure that your computer or other host machine is connected to the same LAN as the Gig...

Page 15: ...evice enable Access Point mode For the other device the Station keep Access Point disabled b Enter a name in the SSID eld This must be the same on both the AP and the Station c In the WPA2 Preshared K...

Page 16: ...DHCP Static Select this option to disable the DHCP client and enter a static IP address c Click Save Changes Repeat the instructions in the Con guration section on the other GigaBeam UNMS Management Y...

Page 17: ...Link Adjust the aim of the AP and the Station to establish a link Note The AP must be aimed rst at the Station because the Station does not transmit any RF signal until it detects transmissions from...

Page 18: ...etween the radios Note Maximum signal strength can best be achieved by iteratively sweeping through both azimuth and elevation 5 Lock the alignment on both radios by tightening all the nuts 6 Observe...

Page 19: ...kg 3 09 lb With Mount 1 8 kg 3 97 lb Enclosure Aluminum UV stabilized Polycarbonate Antenna Gain 5 GHz 11 dBi 60 GHz 38 dBi Networking Interface 1 10 100 1000 Mbps Ethernet Port Max Power Consumption...

Page 20: ...5875 57 000 66 000 Management Radio MHz Worldwide 2412 2472 US CA 2412 2462 Safety Notices 1 Read follow and keep these instructions 2 Heed all warnings 3 Only use attachments accessories speci ed by...

Page 21: ...NMB 3 A Changes or modi cations not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with Part 15 of the FCC Rul...

Page 22: ...l exposition aux rayonnements Cet quipement est conforme aux limites pr vues pour l exposition aux rayonnements dans un environnement non contr l Lors de l installation et de la mise en fonctionnemen...

Page 23: ...he 5 GHz frequency range Note This device is restricted to indoor use only when operating in the 5150 5350 MHz frequency range within all member states Note All countries listed may operate at 30 dBm...

Reviews: