background image

3.  Wrap the Metal Strap around the pole. Use a 7 mm socket 

wrench or screwdriver to turn the screw clockwise and 
securely fasten the strap to the pole.

*640-00176-07*

640-00176-07

Summary of Contents for LiteAP ac LAP-120

Page 1: ...5 GHz 16dBi 120 airMAX AC AP Model LAP 120...

Page 2: ...PoE 24V 0 5A with Mounting Bracket Power Cord Quick Start Guide TERMS OF USE Ubiquiti radio devices must be professionally installed Shielded Ethernet cable and earth grounding must be used as condit...

Page 3: ...nnections and should be grounded through the AC ground of the PoE We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial grade shielde...

Page 4: ...thernet connection is made and flash when there is activity Button Reset Button To reset to factory defaults press and hold the Reset button for more than 10 seconds while the LiteAP is powered on Alt...

Page 5: ...Installation 1 Attach the Ball Joint Mount to the LiteAP by turning the Lock Nut clockwise by hand Do NOT over tighten the nut 2 Open the Metal Strap and feed it through the two slots on the Ball Joi...

Page 6: ...3 Wrap the Metal Strap around the pole Use a 7 mm socket wrench or screwdriver to turn the screw clockwise and securely fasten the strap to the pole 640 00176 07 640 00176 07...

Page 7: ...4 Loosen the Lock Nut to adjust the aim Lock the aim by hand tightening the Lock Nut...

Page 8: ...Connecting Power 1 Remove the Port Cover by pressing down on the center of the cover and sliding it out 2 Connect an Ethernet cable to the Ethernet port 3 Replace the Port Cover...

Page 9: ...r 1 Connect the Ethernet cable from the device s Ethernet port to the POE port of the Gigabit PoE adapter 2 Connect an Ethernet cable from your LAN to the adapter s LAN port 3 Connect the Power Cord t...

Page 10: ...nter PC or return Mac https 192 168 1 20 4 Enter ubnt in the Username and Password fields Select your Country and Language You must agree to the Terms of Use to use the product Click Login Note For th...

Page 11: ...nally installed and it is the professional installer s responsibility to make sure the device is operated within local country regulatory requirements The Output Power field is provided to the profess...

Page 12: ...r Method Passive PoE Pairs 4 5 7 8 Return Supported Voltage Range 20 26VDC ESD EMP Protection 24kV Contact Air Shock and Vibrations ETSI300 019 1 4 Wind Survivability 200 km h 125 mph Wind Loading 77...

Page 13: ...provided only by a qualified service technician 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet a...

Page 14: ...addition made thereto except by Ubiquiti Networks or Ubiquiti Networks authorized representatives or as approved by Ubiquiti Networks in writing II has been painted rebranded or physically modified i...

Page 15: ...LAR PURPOSE AND NON INFRINGEMENT AND ANY WARRANTIES ARISING FROM ANY COURSE OF DEALING USAGE OR TRADE PRACTICE IN CONNECTION WITH SUCH PRODUCTS AND SERVICES BUYER ACKNOWLEDGES THAT NEITHER UBIQUITI NE...

Page 16: ...f implied warranties or conditions so the above exclusion may not apply to you You may have other rights that vary from country to country state to state or province to province Some countries states...

Page 17: ...y with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operat...

Page 18: ...eux conditions suivantes 1 l appareil ne doit pas produire de brouillage 2 l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonc...

Page 19: ...T LU MT NL PL PT RO SE SI SK UK BFWA Broadband Fixed Wireless Access members noted in blue Note This device meets Max TX power limit per ETSI regulations The following apply to products that operate i...

Page 20: ...ice or the shop where you purchased the product Deutsch Die Europ ische Richtlinie 2012 19 EU verlangt dass technische Ausr stung die direkt am Ger t und oder an der Verpackung mit diesem Symbol verse...

Page 21: ...que tout autre mat riel lectrique ou lectronique par les moyens de collecte indiqu s par le gouvernement et les pouvoirs publics des collectivit s territoriales L limination et le recyclage en bonne e...

Page 22: ...om compliance Fran ais French Le soussign UBIQUITI NETWORKS d clare que l quipement radio lectrique du type LAP 120 est conforme la directive 2014 53 UE Le texte complet de la d claration UE de confor...

Page 23: ...clara iei UE de conformitate este disponibil la urm toarea adres internet www ubnt com compliance Sloven ina Slovak UBIQUITI NETWORKS t mto vyhlasuje e r diov zariadenie typu LAP 120 je v s lade so sm...

Page 24: ...ks Inc All rights reserved Ubiquiti Ubiquiti Networks the Ubiquiti U logo the Ubiquiti beam logo airMAX airOS LiteAP and TOUGHCable are trademarks or registered trademarks of Ubiquiti Networks Inc in...