background image

w w w . u b n t . c o m

©2014 Ubiquiti Networks, Inc. All rights reserved. Ubiquiti, Ubiquiti Networks, 
the Ubiquiti U logo, the Ubiquiti beam logo, and mFi are trademarks or 
registered trademarks of Ubiquiti Networks, Inc. All other trademarks are the 
property of their respective owners.

PHRR040414

www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299

Summary of Contents for mFi-LD

Page 1: ...In Wall Manageable Switch Dimmer Model mFi LD www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44 0 1245 808299 ...

Page 2: ...onfiguration The warranty terms are also included in this Quick Start Guide For details on using the mFi Controller or to download the mFi Controller software visit www ubnt com mfi Package Contents mFi Switch Wall Plate In Wall Manageable Switch Dimmer Model mFi LD Wire Nuts Qty 4 Quick Start Guide TERMS OF USE It is the customer s responsibility to follow local country regulations including oper...

Page 3: ...nd regulations WARNING TO AVOID FIRE SHOCK OR DEATH turn off power at the circuit breaker or fuse before installing Wiring Overview Hot Black Ground Green Load Red Neutral White 120V 60 Hz Only use incandescent halogen dimmable CFL or dimmable LED lamps when the mFi Switch is configured as a light dimmer Maximum Load is 5A in Dimmer mode www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44 0...

Page 4: ...d to mFi Controller Flashing blue Connecting to mFi Controller INIT Initialize Button Restores to factory default settings Press and hold until the LED alternates colors to restore the device POWER Air Gap Switch Disconnects power and resets the device Pull the Air Gap Switch out to disconnect power and push the switch back in to restore power When configured as a light dimmer disconnect power bef...

Page 5: ...f there is no Neutral wire run a new circuit containing a Neutral line Hot Load Neutral Ground Electrical Switch Wall Box Note Wiring colors may be different from the illustration Be sure to verify the wiring before continuing 3 Prepare the wiring in the wall box by stripping away 12 mm of insulation from the end of each wire 12 mm www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44 0 1245 ...

Page 6: ...the White wire of the mFi Switch to the Neutral wire of the wall box c Connect the Black wire of the mFi Switch to the Hot wire of the wall box d Connect the Green wire of the mFi Switch to the Ground wire of the wall box Note Orient the mFi Switch with the LED located at the bottom 720 00077 01 720 00077 01 www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44 0 1245 808299 ...

Page 7: ... flush with the wall for proper fitting of the Wall Plate Secure the mFi Switch with the two screws Note Do not over tighten or rely on the force of the screws to pull the mFi Switch into the wall box If the wall box does not have enough room to accommodate the mFi Switch and the wiring replace the wall box with a deeper or wider box www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44 0 124...

Page 8: ...ots on the mFi Switch Press the Wall Plate into position until the mounting clips snap into place If you are using your own wall plate secure it with two screws 8 Turn on power at the circuit breaker or fuse panel www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44 0 1245 808299 ...

Page 9: ... Go to Start Connect To Windows XP Right click the Wireless Network icon in the System Tray lower right corner of the screen Click View Available Wireless Networks 2 Select the wireless network SSID that begins with mFi and then click Connect Go to Accessing the Configuration Portal Mac 1 Click the AirPort icon in the menu bar top right side of the screen 2 Select the wireless network SSID that be...

Page 10: ...c 2 You may receive a security certificate warning Click Proceed Anyway 3 The Configuration Portal will appear Select the wireless network name SSID of your existing wireless network from the drop down list To refresh the list click the blue arrows on the right www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44 0 1245 808299 ...

Page 11: ...er The username used to log in to the Controller Password The password used to log in to the Controller Note Remove the Controller checkmark if you need to enter the Controller settings later This can be done via the embedded UI or layer 2 adoption 6 Click Apply 7 A flashing yellow checkmark will appear while the mFi Switch is attempting to connect to the Wi Fi network It will appear green once th...

Page 12: ...from your wireless network utility 10 If a Controller was specified access the Controller The mFi Switch will appear as a mFi Switch icon in the left panel under the Drag on to Map heading You can position the mFi Switch in the appropriate location For additional details on the mFi Controller software please refer to the mFi User Guide available on our website at documentation ubnt com mfi www 4Go...

Page 13: ...the mFi Switch icon associated with the mFi Switch you would like to configure 2 Click the Configuration icon 3 The Configuration window will appear Under Mode select Dimmer from the dropdown menu Note Only use incandescent halogen dimmable CFL or dimmable LED lamps when the mFi Switch is set to Dimmer mode www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44 0 1245 808299 ...

Page 14: ... Dimmer Mode Interface Status LED Initialize Button Air Gap Switch LED Yellow Blue Wi Fi 802 11b g n Functions Switch or Dimmer Mode Energy Monitoring ESD EMP Protection Air 8KV Contact 4KV Operating Temperature 0 to 40 C 32 to 104 F Operating Humidity 10 to 95 Non Condensing Shock and Vibration 40 C 2 Hrs 85 C 2 Hrs 5 Cycles www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44 0 1245 808299...

Page 15: ...cified may result in improper operation damage to the equipment or pose a fire hazard if the limitations are not followed 2 There are no operator serviceable parts inside this equipment Service should be provided only by a qualified service technician 3 The equipment requires the use of the ground wire as a part of the safety certification modification or misuse can provide a shock hazard that can...

Page 16: ... negligence abnormal physical electromagnetic or electrical stress including lightning strikes or accident V has been damaged or impaired as a result of using third party firmware VI has no original Ubiquiti MAC label or is missing any other original Ubiquiti label s or VII has not been received by Ubiquiti within 30 days of issuance of the RMA In addition the above warranty shall apply only if th...

Page 17: ...ILIATES AND ITS AND THEIR THIRD PARTY PROVIDERS ARE NOT RESPONSIBLE FOR ANY INTERRUPTIONS DELAYS CANCELLATIONS DELIVERY FAILURES DATA LOSS CONTENT CORRUPTION PACKET LOSS OR OTHER DAMAGE RESULTING FROM ANY OF THE FOREGOING In addition UBIQUITI NETWORKS does not warrant that the operation of the Products will be error free or that operation will be uninterrupted In no event shall UBIQUITI NETWORKS b...

Page 18: ...th the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However ther...

Page 19: ...t appareil ne peut pas provoquer d interférences et 2 cet appareil doit accepter toute interférence y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif CAN ICES 3 B NMB 3 B Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment RF Exposure Warning The transceiver described h...

Page 20: ...e product Deutsch Die Europäische Richtlinie 2002 96 EC verlangt dass technische Ausrüstung die direkt am Gerät und oder an der Verpackung mit diesem Symbol versehen ist nicht zusammen mit unsortiertem Gemeindeabfall entsorgt werden darf Das Symbol weist darauf hin dass das Produkt von regulärem Haushaltmüll getrennt entsorgt werden sollte Es liegt in Ihrer Verantwortung dieses Gerät und andere el...

Page 21: ...ue ou électronique par les moyens de collecte indiqués par le gouvernement et les pouvoirs publics des collectivités territoriales L élimination et le recyclage en bonne et due forme ont pour but de lutter contre l impact néfaste potentiel de ce type de produits sur l environnement et la santé publique Pour plus d informations sur le mode d élimination de votre ancien équipement veuillez prendre c...

Page 22: ...QUITI NETWORKS device tyyppinen laite on direktiivin 1999 5 EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen Français French Par la présente UBIQUITI NETWORKS déclare que l appareil UBIQUITI NETWORKS device est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999 5 CE Deutsch German Hiermit erklärt UBIQUITI NETWORKS dass si...

Page 23: ...att denna UBIQUITI NETWORKS device står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999 5 EG Español Spanish Por medio de la presente UBIQUITI NETWORKS declara que el UBIQUITI NETWORKS device cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999 5 CE Polski Polish Niniejs...

Page 24: ...iquiti Networks the Ubiquiti U logo the Ubiquiti beam logo and mFi are trademarks or registered trademarks of Ubiquiti Networks Inc All other trademarks are the property of their respective owners PHRR040414 www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44 0 1245 808299 ...

Reviews: