background image

6

mFi

 Ceiling Mount Motion Sensor

7.  Connect the CAT5/6 cable to the mFi RJ45 Port of the 

mFi‑MSC.

8.  Align the notch on the mFi‑MSC with the notch on the 

Mounting Bracket.

Summary of Contents for MFI-MSC

Page 1: ...Ceiling Mount Motion Sensor Model mFi MSC...

Page 2: ......

Page 3: ...Port Once they are connected you can use the mFi Controller software to monitor your sensors using your Web browser Package Contents g u d mFi Ceiling Mount Motion Sensor Quick Start Guide Mounting Br...

Page 4: ...Motion Sensor Installation Requirements mFi mPort CAT5 6 Cable Phillips Screwdriver Optional Drill and Drill Bit 1 6 mm for M3x50 Flat Head Screws or 6 mm for 3x 20 mm Drywall Screws Hardware Overview...

Page 5: ...here the environmental temperature may change rapidly Locate the mFi MSC at least one meter away from the nearest fluorescent light to avoid interference Ensure there are no obstructions in the field...

Page 6: ...ocation Mark the three screw holes If the CAT5 6 cable is wired above the ceiling mark a 25 mm hole as indicated below 25 mm Hole 3 Use a 1 6 mm drill bit to pre drill holes for the screws 4 If the CA...

Page 7: ...Washers and M3 Keps Nuts Note If you have a drywall ceiling use the 3 x 20 mm Drywall Screws and M6x30 mm Screw Anchors 6 If you have a wiring hole in the ceiling feed the CAT5 6 cable through the Mou...

Page 8: ...6 mFi Ceiling Mount Motion Sensor 7 Connect the CAT5 6 cable to the mFi RJ45 Port of the mFi MSC 8 Align the notch on the mFi MSC with the notch on the Mounting Bracket...

Page 9: ...he other end of the CAT5 6 cable from the mFi MSC to an mFi RJ45 port on the mFi mPort Refer to the User Guide on the CD ROM that was included with your mFi mPort for instructions on configuring the m...

Page 10: ...need to adjust the sensitivity of the microwave sensor however you can turn the knob counter clockwise towards MIN or clockwise towards MAX to make adjustments MAX MIN If you need to access the micro...

Page 11: ...minates when it is triggered see page 10 You can turn on the LEDs permanently or temporarily for walk testing testing the positioning of the mFi MSC The following jumper settings are available Selecti...

Page 12: ...per When the LEDs are enabled the motion sensor will illuminate in one of the following colors when motion is detected Color Detection Indicates that the microwave sensor detected motion Indicates tha...

Page 13: ...nt Bracket Included Mounting Height Up to 4 5 m 15 ft Operating Temperature 0 to 50 C Operating Humidity 5 to 95 Condensing Safety Notices 1 Read follow and keep these instructions 2 Heed all warnings...

Page 14: ...tallation of any item is not included in this warranty The foregoing warranty is exclusive and in lieu of all other warranties express or implied including the implied warranties of merchantability an...

Page 15: ...respects with the applicable Product documentation IV All Ethernet cabling runs use CAT5 or above shielded cabling Disclaimer UBIQUITI NETWORKS does not warrant that the operation of the products is...

Page 16: ...ea is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Industry Canada This Class A digital apparatus complies with Canadian...

Page 17: ...ion distance of at least 20 cm from all persons and must not be located or operating in conjunction with any other antenna or transmitter Les antennes utilis es pour ce transmetteur doivent tre instal...

Page 18: ...mit unsortiertem Gemeindeabfall entsorgt werden darf Das Symbol weist darauf hin dass das Produkt von regul rem Haushaltm ll getrennt entsorgt werden sollte Es liegt in Ihrer Verantwortung dieses Ger...

Page 19: ...due forme ont pour but de lutter contre l impact n faste potentiel de ce type de produits sur l environnement et la sant publique Pour plus d informations sur le mode d limination de votre ancien quip...

Page 20: ...e voldoet aan de essenti le eisen en aan de overige relevante bepalingen van Richtlijn 1999 5 EC English Hereby UBIQUITI NETWORKS declares that this UBIQUITI NETWORKS device is in compliance with the...

Page 21: ...i grunnkr fur og a rar kr fur sem ger ar eru tilskipun 1999 5 EC Italiano Italian Con la presente UBIQUITI NETWORKS dichiara che questo UBIQUITI NETWORKS device conforme ai requisiti essenziali ed all...

Page 22: ...Espa ol Spanish Por medio de la presente UBIQUITI NETWORKS declara que el UBIQUITI NETWORKS device cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la...

Page 23: ......

Page 24: ...Email support ubnt com Phone 9 a m 5 p m PST 408 942 1153 Online Resources Wiki Page wiki ubnt com Support Forum forum ubnt com Downloads downloads ubnt com w w w u b n t c o m 2012 Ubiquiti Networks...

Reviews: