10
II.
Specifications
2.1
General specifications
Subject
Description
Fiber alignment
Ribbon
Applicable fibers
SM(G.652), MM(G.651), DS(G.653), NZDS(G.655),
SM(G.657)
Fiber count
Single fiber, 2~12 Ribbon fiber
Applicable fiber
dimensions
Single: Cladding diameter 125
μ
m, Coating diameter
250
μ
m, 900
μ
m
Ribbon: Cladding diameter 125
μ
m, Ribbon fiber
thickness 0.25 to 0.40mm
Fiber cleave length
10mm
Splicing modes
Splicing: 300, Heat: 100, Strip: 50
Average splice Loss
SM: 0.05dB, MM: 0.02dB, DS: 0.08dB, NZDS: 0.08dB
Return loss
> 60dB
Splicing time
Typical 20 sec with standard SM (ITU-T G.652)
Splice loss estimate
Available
Sleeve heating time
1~2 core 20 sec
4~12 core 50 sec
Applicable protection
sleeve
40mm, 60mm (Fiber)
Storage of splice
result
The last 10,000 results to be stored in the internal
memory. (Image 10,000 results)
Tension test
2N / 4.4N (Option)