22
3.2.5 Swift KR12A Cleaver
The cleaver is designed to cleave the fiber at a 90 degree angle.
For the best result, following requirements should be met.
i.
The coating of fiber shall be cleanly stripped.
ii.
The fiber shall be properly placed on the holder upon cleaving.
iii.
The physical condition and height of the cleaver blade shall be adequately
maintained.
<Front> <Bottom>
Be careful not to wet the equipment
Maintain the unit in a clean condition at all times because many of splicing
problems are caused by dust or moisture.
Keep and use the unit at room temperature as it could be deformed by heat.
Keep the equipment from being shaken or physically impacted as it could be
broken.
Never use organic solvents such as acetone except alcohol to clean rubber
part of the equipment.
Cover
Clamp
Blade
Cleaver Body
Slider
Set Screw
Rack Gear
Damper