77
6.6.2 Motor Drive
It checks the operating status of the motor manually.
i.
Place the fiber in the splicer.
ii.
Click “Motor Drive”.
iii.
To select a motor. The name of the selected motor is displayed at the top
left on the screen.
iv.
Use
to move the selected motor to a desired direction.
Motor
ZL/ZR
ZL/ZR Move forward.
ZL/ZR Move backward.
S
Move step by step press a button.
M
Move while pressing a button.
6.6.3 Arc Calibration
The arc calibration is; the variation of temperature, humidity and air pressure has
been detected by internal sensors continuously. Based on such a variation, supply a
feedback data into the monitoring system to adjust an arc power a constant level.
Additionally the changes in arc power due to the abrasion of the electrode and glass
adhesion are not automatically calibrated. Also, the center axis of arc discharge may
be moved to left or right. Thus the fiber splicing position is not matched to arc
discharge center. For this reason, Arc calibration is required.