background image

BLE RS-232 adapter user manual V1.1 

 

2017.06.07 

 

2.2 DB9 connector: 

There’re 2 screws and 2 nuts inside the package, the screw or nut are available. 

         

   

 

2.3 Rear Side: 

             

 

 

Switch configuration: 

Setup 

CTS/RTS 

Stop Bit  Parity 

Role 

Baud Rate 

6-5 

3-2-1 

0: Switch 

1: Command 

0: Disable 

1: Enable 

0: 1 

1: 2   

00: None 

01: Odd 

10: Odd 

11: Even 

0:Slave 

1:Master 

110:2400 

111:4800 

000:9600 

001:19200 

010:38400 

011:57600 

100:115200 

101:230400 

Remark:   

1. 000000000 by default, in 

red bold

 character 

2. The GATT service and AT command will support more settings than the DIP switch, 

please check the page 4 section 5 and page 5 section 6. 

DIP Switch 

  DCE 

  DTE 

Screw 

Nut 

Nut 

Screw 

Summary of Contents for BLE-232B

Page 1: ...Weight 105 g Package Contents BLE RS 232 adapter x 1 Screw x2 Screw nut x 2 A4 User manual x 1 Mini USB Cable x 1 2 Profile 2 1 Top view LED Status Description Data LED flash Data transmission Data L...

Page 2: ...Rate 9 8 7 6 5 4 3 2 1 0 Switch 1 Command 0 Disable 1 Enable 0 1 1 2 00 None 01 Odd 10 Odd 11 Even 0 Slave 1 Master 110 2400 111 4800 000 9600 001 19200 010 38400 011 57600 100 115200 101 230400 Remar...

Page 3: ...please choose one Don t power the adapter by more than two sources 3 3 The mini USB cable is inside the standard package 4 Specifications 4 1 Default value Baud rate 9 600 bps Data bit 8 Parity none...

Page 4: ...20 bytes 00031234 0000 1000 8000 00805F9B0131 UUID_MacID 6 bytes 00031234 0000 1000 8000 00805F9B0133 UUID_DeviceName 15 bytes 00031234 0000 1000 8000 00805F9B0134 UUID_Reboot 1 bytes 00031234 0000 10...

Page 5: ...mmand set via COM port Command Value Description AT Check the connection status between control terminal and the RS 232 adapter Response OK when the connection is ok Response ERROR when the connection...

Page 6: ...LT The command will need 1 second delay Default N Disable flow control Y Enable flow control Inquire the current setting NAME This command is used to specify a device name for the adaptor You can spec...

Page 7: ...4 to 1 Master The central will link with the neighboring peripheral automatically The blue LED will be solid on The central will link with the paired peripheral on next time when power on Please rese...

Page 8: ...Connect and configure Data transmission test Download Android iOS Remark Please contact the supplier for the APP download or the sample code Disconnect TX area RX area Data mode Clear data and log De...