2.4 RS232 Interface (Female) 

 

Pin 

Signal 

DTE Direction 

DCE Direction 

Description 

N/A 

 

 

 

TxD 

Output 

Input 

Transmitted data 

RxD 

Input 

Output 

Received data 

N/A 

 

 

 

GND 

 

 

Ground 

N/A 

 

 

 

CTS 

Input 

Output 

Clear to send 

RTS 

Output 

Input 

Request to send (Default) 

VCC 

 

 

Power Input (5~27 VDC) 

 

3. Power supply: 

3.1 Voltage: 5~27 VDC, 

Don’t exceed the limit.

 

3.2 There’re 3 ways to power the adapter: Mini USB, Terminal Block and pin9 of DB9, 

please choose one.  

Don’t power the adapter by more than two sources.

 

3.3 The mini USB cable is inside the standard package. 

 

4. Specifications: 

4.1 Default value: 

 

Baud rate: 9,600 bps 

 

Data bit: 8 

 

Parity: none 

 

Stop bit: 1 

 

Flow control: none 

 

Device Name: BLE 232 

 

4.2 All function of COM port: 

 

Baud Rate: 1.2/2.4/4.8/9.6/19.2/38.4/57.6/115.2/230.4/460.8/921.6 Kbps 

 

Parity: none/even/odd 

 

Stop bit: 1/1.5/2 

 

Data bit: 7/8 

Remark: The GATT service and AT command will support all the functions, please 

check the page 4 section 5 and page 5 section 6. 

4.3 Range: max. 50 m in open space 

4.4 TX Power: Max. 3 dBm 

4.5 RX Sensitivity: -89 dBm typical 

4.6 TX current consumption of 15.6 mA (radio only, 0 dbm) 

Summary of Contents for BLE-232B

Page 1: ...Weight 105 g Package Contents BLE RS 232 adapter x 1 Screw x2 Screw nut x 2 A4 User manual x 1 Mini USB Cable x 1 2 Profile 2 1 Top view LED Status Description Data LED flash Data transmission Data L...

Page 2: ...Rate 9 8 7 6 5 4 3 2 1 0 Switch 1 Command 0 Disable 1 Enable 0 1 1 2 00 None 01 Odd 10 Odd 11 Even 0 Slave 1 Master 110 2400 111 4800 000 9600 001 19200 010 38400 011 57600 100 115200 101 230400 Remar...

Page 3: ...please choose one Don t power the adapter by more than two sources 3 3 The mini USB cable is inside the standard package 4 Specifications 4 1 Default value Baud rate 9 600 bps Data bit 8 Parity none...

Page 4: ...20 bytes 00031234 0000 1000 8000 00805F9B0131 UUID_MacID 6 bytes 00031234 0000 1000 8000 00805F9B0133 UUID_DeviceName 15 bytes 00031234 0000 1000 8000 00805F9B0134 UUID_Reboot 1 bytes 00031234 0000 10...

Page 5: ...mmand set via COM port Command Value Description AT Check the connection status between control terminal and the RS 232 adapter Response OK when the connection is ok Response ERROR when the connection...

Page 6: ...LT The command will need 1 second delay Default N Disable flow control Y Enable flow control Inquire the current setting NAME This command is used to specify a device name for the adaptor You can spec...

Page 7: ...4 to 1 Master The central will link with the neighboring peripheral automatically The blue LED will be solid on The central will link with the paired peripheral on next time when power on Please rese...

Page 8: ...Connect and configure Data transmission test Download Android iOS Remark Please contact the supplier for the APP download or the sample code Disconnect TX area RX area Data mode Clear data and log De...

Reviews: