background image

BLE RS-485 Serial Adapter

 

user manual V1.1 

- 2 - 

 

2. Rear view: 

           

 

Setup 

Modbus 

Stop Bit 

Parity 

Role 

Baud Rate 

DIP9 

DIP8 

DIP7 

DIP6    DIP5 

DIP4 

DIP3 DIP2 DIP1 

0: Switch 

1: Command

 

0: Normal 

1: Modbus RTU

 

0: 1 

1: 2

 

00: None 

01: Odd 

10: Odd 

11: Even

 

0:Slave 

1:Master

 

110:2400 

111:4800 

000:9600 

001:19200 

010:38400 

011:57600 

100:115200 

101:230400 

Remark: 

1. 000000000 by default, in 

red bold

 character 

2. The GATT service and AT command will support more settings than the DIP switch, 

please check the page 4 section 5 and page 5 section 6.

 

 

3. Power supply: 

3.1 Voltage: 5~27 VDC, 

Don’t exceed the limit.

 

3.2 There’re 3 ways to power the adapter: Mini USB, Terminal Block and pin9 of DB9, 

please choose one.  

Don’t power the adapter by more than two sources.

 

3.3 The mini USB cable is inside the standard package. 

 

4. Specifications: 

4.1 Default value: 

 

Baud rate: 9,600 bps 

 

Data bit: 8 

 

Parity: none 

 

Stop bit: 1 

 

Flow control: none 

 

Device Name: BLE 232 

DIP Switch 

  RS-485 

  RS-422 

Terminal Block 

Summary of Contents for BLE-485C

Page 1: ...Weight 105 g Package Contents BLE 422 485 adapter x 1 Screw x2 Screw nut x 2 A4 User manual x 1 Mini USB Cable x 1 2 Profile 2 1 Top view LED Status Description Data LED flash Data transmission Data...

Page 2: ...cter 2 The GATT service and AT command will support more settings than the DIP switch please check the page 4 section 5 and page 5 section 6 3 Power supply 3 1 Voltage 5 27 VDC Don t exceed the limit...

Page 3: ...radio only 0 dbm 4 7 Operation Temperature 40 C to 70 C 4 8 Dimensions 81 6 mm L x 31 75 mm W x 17 mm H 4 9 Antenna Gain max 2 dB Remark All contents are subject to change without notice 5 GATT Servi...

Page 4: ...e1 Byte2 Byte3 Data bit Hwfc Stop Bit Parity Bit 7 8 0x01 on 0x00 off 2 1 3 1 5 4 2 0x02 No Parity 0x01 Odd Parity 0x00 Even Parity Byte4 Byte5 Byte6 Baud Rate Device Mode Reset To Default 00 9600 01...

Page 5: ...choed back to the DTE DCE Default Y Command characters received from the UART are echoed back to the DTE DCE Inquire the current setting FLOW This command enable or disable flow control signals CTS RT...

Page 6: ...hanged the adaptor will reboot and all paired addresses will be cleared C Set the adaptor to the central role Default P Set the adaptor to the peripheral role Inquire the current role of the adaptor S...

Page 7: ...al Then select the other one as the peripheral and link The central will link with the neighboring peripheral automatically The blue LED will be solid on The central will link with the paired peripher...

Page 8: ...BLE RS 485 Serial Adapter user manual V1 1 8 APP Download Android iOS APP Sample code Please contact the supplier for the test sample code...